page 36 — DCa45SSIU4 60 hz generator • operatIon anD partS manUal — rev. #1 (10/24/13)
generatOr shut-DOWn prOceDures
2. Place the engine speed switch (Figure 53) in the “
loW
”
(down) position..
Figure 53. Ignition Switch (Normal)
3. Let the engine cool by running it at low speed for 3-5
minutes with no load applied.
4. Place the
mpeC Control Switch
(Figure 54) to the
oFF/reSet
position.
Figure 54. MPEC Control Switch (Off/Reset)
5. Verify that
all
status LEDs on the MPEC display are
OFF
(not lit).
6. Remove all loads from the generator.
7. Inspect entire generator for any damage or loosening
of components that may have occurred during
operation.
emergenCY ShUtDoWn proCeDUre
1. Place the
mpeC Control Switch
(Figure 54) in the
oFF/reSet
position.
11. Place the
main, gFCI, and aux.
circuit breakers in the
ON
position (Figure 50).
Figure 50. Main, Aux. and GFCI
Circuit Breakers (ON)
12. Observe the generator’s ammeter (Figure 51) and
verify it reads the anticipated amount of current with
respect to the load. The ammeter will only display a
current reading if a load is in use.
Figure 51. Ammeter (Load)
13. The generator will run until manually stopped or an
abnormal condition occurs.
normal ShUtDoWn proCeDUre
To shutdown the generator, use the following procedure:
1. Place both the
maIn, gFCI and loaD
circuit breakers
as shown in Figure 52 to the
OFF
position..
Figure 52. Main, GFCI and Load
Circuit Breakers Off
WARNING
never
stop the engine suddenly except in an
emergency.
Summary of Contents for Power WhisperWatt DCA45SSIU4
Page 19: ...DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 page 19 Notes...
Page 52: ...page 52 DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 GENERATOR ASSY...
Page 54: ...page 54 DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 control box ASSY...
Page 56: ...page 56 DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 control box ASSY...
Page 58: ...page 58 DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 control box ASSY...
Page 66: ...page 66 DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 BATTERY ASSY...
Page 68: ...page 68 DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 Muffler Assy...
Page 70: ...page 70 DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 FUEL TANK ASSY...
Page 76: ...page 76 DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 RUBBER SEALS ASSY...
Page 81: ...DCA45SSIU4 60 hz Generator operation and parts manual rev 1 10 24 13 page 81 notes...