dca150ssju4f 60 hz generator• operation manual — rev. #0 (11/0614) — page 35
GeNeratOr shUt-DOWN prOCeDUres
normal shutdoWn procedure
To shutdown the generator, use the following procedure:
1. Place both the
main, gfci and load
circuit breakers
as shown in Figure 48 to the
OFF
position.
Figure 48. Main, Aux. and GFCI
Circuit Breakers (OFF)
2. Let the engine cool by running it at low speed for 3-5
minutes with no load applied.
3. Place the
auto off/reset manual switch
(Figure 49)
in the
off/reset
position.
Figure 49.
auto off/reset manual
itch
(Off/Reset)
4. Verify that all status LEDs on the ECU control panel
are
OFF
(not lit).
5. Remove all loads from the generator.
6. Inspect entire generator for any damage or loosening of
components that may have occurred during operation.
Warning
never
stop the engine suddenly except in an
emergency.
MAIN
CIRCUIT
BREAKER
GFCI
CIRCUIT
BREAKER
AUXILIARY
CIRCUIT
BREAKER
AUTO
MANUAL
OFF/RESET
(CENTER)
emergencY shutdoWn procedure
1. Place the
auto off/reset manual switch
(Figure 50)
in the
off/reset
position.
Figure 50.
auto off/reset manual
Sw
itch (OFF)
AUTO
MANUAL
OFF/RESET
(CENTER)
Summary of Contents for Whisperwatt DCA150SSJU4F
Page 5: ...DCA150ssju4f 60 hz generator operation manual rev 0 11 0614 page 5 notes ...
Page 56: ...page 56 dca150ssju4f 60 hz generator operation and Parts manual rev 0 11 06 14 GENERATOR ASSY ...
Page 72: ...page 72 dca150ssju4f 60 hz generator operation and Parts manual rev 0 11 06 14 battery ASSY ...
Page 74: ...page 74 dca150ssju4f 60 hz generator operation and Parts manual rev 0 11 06 14 muffler ASSY ...
Page 78: ...page 78 dca150ssju4f 60 hz generator operation and Parts manual rev 0 11 06 14 fuel tank ASSY ...
Page 80: ...page 80 dca150ssju4f 60 hz generator operation and Parts manual rev 0 11 06 14 ENCLOSURE ASSY ...
Page 93: ...DCA150ssju4f 60 hz generator operation manual rev 0 11 0614 page 93 notes ...