page 18 — DCa300SSC / DCa300SSCU gen. • operation anD partS manUal — rev. #1 (08/10/11)
generatOr cOntrOL paneL
Figure 4. Generator Control Panel
The definitions below describe the controls and functions
of the Generator Control Panel (Figure 4).
1.
pilot lamp
— Indicates the system is running.
2.
panel light
— Normally used in dark areas or at night
time. When activated, panel lights will illuminate. When
the generator is not in use be sure to turn the panel
light switch to the
oFF
position.
3.
aC voltmeter
— Indicates the output voltage present
at the
U,v, and W output terminal lugs.
4.
auto on/off engine Controller (mpeC) —
This controller has a vertical row of status LED’s (inset),
that when lit, indicate that an engine malfunction (fault)
has been detected. When a fault
has been detected the engine
controller will evaluate the fault
and all major faults will shutdown
the generator. During
cranking
cycle
, The MPEC will attempt to
crank the engine for 10 seconds
before disengaging.
If the engine does not engage (start) by the third
attempt, the engine will be shutdown by the engine
controller’s
over Crank protection
mode. If the
engine engages at a speed (RPM’s) that is not safe,
the controller will shutdown the engine by initializing
the
over Speed protection
mode.
5.
main Circuit Breaker
— This three-pole, 800 amp
main breaker is provided to protect the
U,v, and W
output terminal lugs
from overload.
6.
voltmeter Change-over Switch
— This switch allows
the AC voltmeter to indicate phase to phase voltage
between any two phases of the output terminals or to
be switched off.
7.
voltage regulator Control
— Allows ±15% manual
adjustment of the generator’s output voltage.
8.
panel light Switch
— When activated will turn on
control panel light.
9.
ammeter Change-over Switch
— This switch allows
the AC ammeter to indicate the current flowing to the load
connected to any phase of the output terminals, or to be
switched off. This switch does not effect the generator
output in any fashion, it is for current reading only.
10.
AC Ammeter
— Indicates the amount of current the
load is drawing from the generator per leg selected by
the ammeter phase-selector switch.
11.
Frequency meter
— Indicates the output frequency
in hertz (Hz). Normally 60 Hz
Summary of Contents for WhisperWatt DCA300SSC
Page 21: ...DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 page 21 Notes ...
Page 49: ...DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 page 49 NOTES ...
Page 53: ...DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 page 53 notes ...
Page 56: ...page 56 DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 GENERATOR ASSY ...
Page 60: ...page 60 DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 control box ASSY ...
Page 78: ...page 78 DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 muffler ASSY ...
Page 84: ...page 84 DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 enclosure ASSY ...
Page 92: ...page 92 DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 RUBBER SEALS ASSY ...
Page 103: ...DCA300SSC DCA300SSCU Gen operation and parts manual rev 1 08 10 11 page 103 notes ...