background image

PAGE 24 — STXD6i RIDE-ON TROWEL• OPERATION MANUAL — REV. #2 (05/28/15) 

OPERATION

STARTING THE ENGINE

1.  With one foot on the ground and the other foot placed 

on the trowel’s platform, grasp the grab handles lifting 

yourself onto the trowel. Then sit down in the operator’s 

seat.

2.  This trowel is equipped with a Safety Bypass Switch. 

The trowel will not move unless an operator is sitting in 

the seat. While the engine can be started or continue 

to run with the operator off the seat, the rotors will not 

rotate. The weight of an operator activates a switch 

within the seat allowing the rotors to turn.

  WARNING

NEVER

 operate the trowel in a confined 

area or enclosed area structure that does 

not provide ample free flow of air.

  CAUTION

ALWAYS

 wear approved eye and hearing 

protection before operating the ride-on 

power trowel. 

  CAUTION

NEVER

 place hands or feet inside the guard rings while 

the engine is running. 

ALWAYS

 shut the engine down 

before performing any kind of maintenance service on 

the trowel.

 NOTICE

DO NOT

 grab hold of the joysticks to lift yourself onto 

the trowel. Pulling on the joysticks repeatedly will 

weaken the units. ALWAYS use the grab handles to lift 

yourself on the trowel.

  WARNING

NEVER

 disable or disconnect the Safety Bypass 

Switch. It is provided for the operator's safety. Injury 

may result if it is disabled, disconnected or improperly 

maintained.

3.  Insert the ignition key into the ignition switch (Figure 11).

Figure 11. Ignition Switch and Key

4.  Turn the ignition key clockwise to the 

ON

 position. 

Aux1

Aux 2

, Coolant Temp, Cruise, Pitch Mode Lights 

will light for 10 seconds (Figure 12) and Charge Lamp 

will remain on until engine starts. Coolant fan will run 

for 10 seconds.

Figure 12.  Indicator Lights

5.  Turn the ignition key fully clockwise to the 

START 

position. Once the engine has started, release the 

ignition key. The throttle speed defaults to idle to allow 

the engine to warm to operating temperature.

6.  Repeat this section a few times to get fully acquainted 

with the engine starting procedure.

 NOTICE

It is recommended that the operation of the Safety Stop 

Switch is checked prior to performing any troweling 

operations. Doing this will verify that the switch is 

working properly contributing to safe operation of the 

machine. 

OFF ON

PREHEAT

(Unused)

ACC

(Unused)

START

 NOTICE

If the hydraulic temperature is below 135° F during the 

start process, the 

AUX1

 light will remain on to indicate 

that the unit is in cold start mode. Refer to Cold Start 

section for operation.

Summary of Contents for Whiteman STXD6i

Page 1: ...ACCOMPANY THE EQUIPMENT AT ALL TIMES To find the latest revision of this publication visit our website at www multiquip com SERIES MODEL STXD6i HYDRAULIC RIDE ON TROWEL YANMAR 4TNV84T Z DSA2 DIESEL EN...

Page 2: ...PAGE 2 STXD6i RIDE ONTROWEL OPERATION MANUAL REV 2 05 28 15 PROPOSITION 65 WARNING Diesel engine exhaust and some of...

Page 3: ...cancer birth defects or other reproductive harm If you are unfamiliar with the risks associated with the particular process and or material being cut or the composition of the tool being used review t...

Page 4: ...3 Table Of Contents 4 Training Checklist 6 Daily Pre Operation Checklist 7 Safety Information 8 3 Lifting And Transporting 14 Specifications 15 Dimensions 16 General Information 17 Components 18 19 B...

Page 5: ...STXD6i RIDE ONTROWEL OPERATION MANUAL REV 2 05 28 15 PAGE 5 NOTES...

Page 6: ...ls 3 Fuel system refueling procedure 4 Operation of spray and lights 5 Operation of controls machine not running 6 Safety controls safety stop switch operation 7 Emergency stop procedures 8 Startup of...

Page 7: ...28 15 PAGE 7 DAILY PRE OPERATION CHECKLIST Daily Pre Operation Checklist 1 Engine oil level 2 Hydraulic oil level 3 Radiator coolant level 4 Condition of blades 5 Blade pitch operation 6 Safety stop...

Page 8: ...ceded by one of four words DANGER WARNING CAUTION or NOTICE SAFETY SYMBOLS DANGER Indicates a hazardous situation which if not avoided WILL result in DEATH or SERIOUS INJURY WARNING Indicates a hazard...

Page 9: ...e working area when the equipment is in operation DO NOT use the equipment for any purpose other than its intended purposes or applications NOTICE This equipment should only be operated by trained and...

Page 10: ...n a running machine NEVER place your feet or hands inside the guard rings while starting or operating this equipment DANGEROUS GAS FUMES NOTICE ALWAYS keep the machine in proper running condition Fix...

Page 11: ...a hot engine BATTERY SAFETY DANGER DO NOT drop the battery There is a possibility that the battery will explode DO NOT expose the battery to open flames sparks cigarettes etc The battery contains comb...

Page 12: ...ry heights ALWAYS tie down equipment during transport by securing the equipment with straps Inspect straps to make sure they are not frayed or damaged TOWING SAFETY CAUTION Check with your local count...

Page 13: ...or lead reclamation Use safety precautions when handling batteries that contain sulfuric acid When the life cycle of this equipment is over it is recommended that the trowel frame and all other metal...

Page 14: ...insert forklift forks through loops at the end of lifting straps NOTICE Ensure forklift has adequate lifting capacity for lifting the trowel TRANSPORTINGTHETROWEL After trowel has been lifted onto a f...

Page 15: ...gine Specifications MODEL Yanmar 4TNV84T Z DSA2 Type Vertical 4 cycle water cooled diesel engine direct injected turbocharged No of Cylinders 4 Bore X Stroke 3 31 in x 3 54 in 84 mm x 90 mm Displaceme...

Page 16: ...mended Table 1 3 The vibration level indicated is the maximum RMS Root Mean Square value obtained at the handle grip while operating the ride on trowel on curing concrete in a manner most often experi...

Page 17: ...r trowel test it on a flat watered down section of finished concrete This trial test run will increase your confidence in using the trowel and at the same time it will familiarize you with the trowel...

Page 18: ...m fuel preventing engine component wear 7 Cruise Control Switch Press this switch to engage the cruise control Press again to disengage 8 Pitch Block Behind grill guard Measure at the service port and...

Page 19: ...Control left side Allows the unit to move in a forward or reverse direction only 30 Steering Control right side Allows the unit to move in either a forward reverse left or right direction 31 Grill Gu...

Page 20: ...9 Injection Pump Provides equal fuel flow to injectors 10 Oil Filter Spin on type filters oil for contaminants 11 Oil Pressure Switch Monitors oil level 12 Oil Dip Stick Remove to check amount and con...

Page 21: ...operation of the STXD6i Ride OnTrowel could result in personal injury or severe damage to the trowel ENGINE OIL FILLER CAP ENGINE OIL FILLER CAP DIPSTICK F L ADD OIL FULL CAUTION DO NOT overfill the o...

Page 22: ...handling equipment clean at all times Poor quality fuel can reduce engine performance and or cause engine damage Fuel additives are not recommended Some fuel additives may cause poor engine performan...

Page 23: ...ervice until the setup instructions are completed These instructions only need to be performed at the time of unpacking a new trowel CAUTION Use all safety precautions specified by the battery manufac...

Page 24: ...the grab handles to lift yourself on the trowel WARNING NEVER disable or disconnect the Safety Bypass Switch It is provided for the operator s safety Injury may result if it is disabled disconnected o...

Page 25: ...remain on until the unit reaches 140 F In the hydraulic system or at a default time of 30 minutes THROTTLE SWITCH CRUISE CONTROL SWITCH Hydraulic cooling fan will come back on and the hydraulic fluid...

Page 26: ...ted and oil is at operating temperature FAULT ALERTING Red Stop Lamp This lamp is used to relay trouble code information that is severe enough to warrant stopping the trowel due to a detected fault co...

Page 27: ...2 Pushboththeleftandrightjoysticksforward Figure18 Figure 18 Joystick Control Forward Direction 3 With your right foot slowly depress the foot pedal halfway Notice that the ride on trowel begins to m...

Page 28: ...tch 3 position center off is pressed the pitch on the left rotor will be changed while the pitch on the right rotor remains constant The Pitch Mode Light will turn off to indicate pitch function is in...

Page 29: ...o idle for 5 minutes Figure 21 Engine Shutdown 2 Turn the ignition key counterclockwise to the OFF position then remove the key 3 Clean and remove any foreign debris from the trowel THROTTLE SWITCH CR...

Page 30: ...th New Coolant X or yearly which ever comes first Check Engine Oil Level X Drain and Fill Engine Oil X 1st time X 2nd time and after Replace Engine Oil Filter X 1st time X 2nd time and after Check and...

Page 31: ...lure MAINTENANCE Air Cleaner Service To service the air cleaner perform the following steps See Figure 22 for location of parts 4 Release the latches located on either side of the air cleaner dust pan...

Page 32: ...ter than 28 psi 193 kPa or a wire brush to clean the radiator fins Radiator fins damage easily FAN BELTTENSION A slack fan belt may contribute to overheating or to insufficient charging of the battery...

Page 33: ...ERATURE RANGE EXPECTED BEFORE NEXT OIL CHANGE 20 0 20 SAE 15W 40 30 SAE 10W 30 32 40 60 80 100 30 20 10 0 10 20 30 40 10W 20W OIL FILLER CAP DIP STICK OIL FILTER OIL DRAIN PLUG MAINTENANCE 5 Clean sea...

Page 34: ...e front of this manual is a Daily Pre Operation Checklist Make copies of this checklist and use it on a daily basis ALWAYS disconnect battery cables before attempting any service or maintenance on the...

Page 35: ...r Pan Installation 1 Lift trowel just enough to slide pan under blades Lower finisher onto pan with blades adjacent to Z Clips 2 Rotate blades into position under Z Clips Ensure that the blades are ro...

Page 36: ...ck the trowel arm bushings for tightness This can be done by moving the trowel arms up and down If there is more than 1 8 3 2 mm of travel at the tip of the arm the bushings should be replaced All bus...

Page 37: ...er on off switch Replace if broken Bad spray pump If pump has a voltage present when the switch is turned on but does not operate and electrical connections to the pump are good replace the pump Bad f...

Page 38: ...oil too thick Refill engine crankcase with correct type of oil for winter environment Defective battery Replace battery Engine fires but stops soon as starter is switched off Fuel filter blocked Repl...

Page 39: ...adiator or radiator cap defective Replace defective part Thermostat defective Check thermostat and replace if necessary Head gasket defective or water leakage Replace parts Engine oil pressure indicat...

Page 40: ...eld Cheshire SK16 4UJ Contact sales multiquip co uk Tel 0161 339 2223 Fax 0161 339 3226 COPYRIGHT 2015 MULTIQUIP INC Multiquip Inc the MQ logo and the Whiteman logo are registered trademarks of Multiq...

Reviews:

Related manuals for Whiteman STXD6i