background image

DESCRIPTION

Time - 1

Delayed OFF

Unit - 2 for Time - 2

Cycling time

Minute set for Time - 1 or 2

Up counting

Memory Retain : Yes / No
Enable Trigger Power ON

DISPLAY

SR.

1

6

10

 8

4

12

15

Time - 2

Password

Unit - 1 for Time - 1

Delayed function

Seconds set for Time - 1 or 2

Direction of time counting

Delayed ON

Hour set for Time - 1 or 2

Down counting

2

7

3

11

14

 9

5

13

16

17

T M 1

T M 2

p a s

F U N 

C Y L 

D O N

D O F

U N 1

U N 2

S E C

M I n

H R
d I r

U P

m E M

P L S

D N

Page - 3

www.multispanindia.com

UTR-413

1).   Turn ON instrument. SET time according to your requirement.
2).   In running mode, upper display indicates current TIME value and lower display shows SET 
        time value. Relay ON or OFF controls depends on set time.
3).   Relay operation is according to selection of Delay ON or Delay OFF in programming menu.
4).   In cycling mode, relay will turn on for ON time (time-1) & relay will turn off for OFF time 
        (time-2) and this ON-OFF process will continue.
5).   To reset the time, press Reset Key.

Working

Set time mode

Display Message And Their Meaning

T I m

1 2 3 

T M 1

1 2 3 

Cycle OFF time (time-2)

press            key to 
set cycle ON time

press            key to 
set cycle OFF time

press            key to 
                   set time

T M 2

1 2 3 

If Delayed ON/ Delayed OFF is selected

If Cycling Mode is selected

Press      key  

SET

Press      key  

SET

Press      key  

SET

Press     key to save & exit

RESET

ENT