background image

Installing a Ground Wire 

Proper grounding of the metal enclosure is required to ensure safety. There are two 
ground lugs and one ground screw located on the enclosure back as shown in the 

Back

 image (under 

Connector Locations

). Connecting a ground lug to an earth ground is the recommended method. Refer to the National 

Electric Code or your local codes for additional information or contact a licensed electrician for assistance in grounding an installation.  

Ground wire (not provided) must be suitable for outdoor location and meet a minimum wire gauge of 14awg or larger. Use the 
supplied ground screw to fasten wire. 

Ground wire terminal (not provided) must be closed loop (ring type, see image right) and corrosive free in design. Insert 

screw through loop terminal and fasten to 15 lbf.in (17.28 kfg.cm).  

You can use either ground lug with the ground screw to connect the ground wire to the enclosure. 

Attaching Antennas

 

After mounting the Base Station:   

Note: 

All antennas should be finger-tightened plus a quarter turn.

 

1.  For LTE models, attach the LTE cellular antennas to the Cell (5) and Diversity (6) connectors on the bottom 

of the Base Station.  

2.  Attach the GPS antenna to the GPS (3) connector on the top of the Base Station.  
3.  For Wi-Fi/Bluetooth models, attach the Wi-Fi antenna to the Wi-Fi (2) connector on the top of the Base Sta-

tion.  

4.  Attach the LoRa antenna(s) to the LoRa (1) and (4) connectors at the top of the Base Station. If only one 

LoRa antenna, install on LoRa (1) connector.  

 

If attaching LoRa antennas away from the Base Station, go to 

Attaching LoRa Antennas via Cable

.  

5. 

Go to 

Connecting Ethernet 

for steps on connecting the Base Station to power and 

Ethernet.

 

Connecting Ethernet  

 

Note:

 This is an 802.3at Type 2 device. It needs a power input of at least 25W from standard 802.3at PoE input. For more information 

refer to 

the Conduit PoE Application Note 

(S000678) available at 

www.multitech.net/developer/basestation

  

To connect your Ethernet cable and PoE injector:  

1.  Remove the sealing nut, clamping claw, and sealing insert. 
2.  Thread the Ethernet cable (not provided) through the sealing nut 
3.  Wrap the sealing insert around the cable and the clamping claw over the sealing insert.  
4.  Plug the Ethernet cable into the Ethernet port.  
5.  Push the seal and clamping claw into the cable gland body.  
6.  Push the sealing nut over the insert and clamping claw and tighten on the cable gland body to 10.5 lbf in (12.0 kgf cm).  

Best Practices

 

We recommend covering all connections with a rubber insulating tape, such as 3M’s130C. Although the Base Station is rated IP67,  
taping provides additional protection against environmental 

particulates

.  

Next Steps 

After connecting and powering up the Base Station, refer the 

 Conduit Base Station IP67 Getting Started Guide (S000665) 

and related 

documentation available at 

www.multitech.net/developer/basestation

 

Regulatory Information 

This device complies with Part 15 of the FCC rules and with ICES-003 of industry Canada for a Class A digital apparatus. Operation 

of this device is subject to the following conditions: (1) This device may not cause harmful interference and (2) This device must ac-

cept any interference that may cause undesired operation.   

 

MultiTech declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 

2014/53/EU. The declaration of conformity may be requested at 

https://support.multitech.com

 

Installing a Micro SIM Card 

To install a SIM card: 

1.  Remove the SIM/USB cover. The SIM holder is above the USB port. 
2.  Gently push the micro SIM card into the holder with the cut corner to the left 

and the SIM contacts facing towards the USB port as shown.  

3.  Reattach the plastic cover and tighten to 10.5 lbf.in (12 kgf.cm). 

Attaching the Mounting 

Bracket 

To attach the mounting bracket to the Base Station: 

 

Attach the bracket to the back of the Base Station using the supplied 
screws and washers as shown (right).

 

Mounting on a Wall 

To mount the device on a wall:  

 

Use the four bracket tabs to attach the Base Station to the 
wall with the supplied screws and anchors as shown below.

 

Mounting on a Pole 

To attach the Base Station on a pole: 

 

 

Attach the Base Station to the pole using the supplied hose 
clamps as shown below. 

 

Attaching LoRa Antennas via Cable  

Recommended for this option: 

Lightning arrestor, coaxial cable, and mounting bracket for each 

LoRa antenna. Refer to 

Related Accessories 

for details. 

 After attaching other antennas:  

1.  Use an antenna hose clamp to attach the antenna bracket to 

a LoRa antenna.  

2.  Attach the lightning arrestor (optional) to the antenna as 

shown (right). 

3.  Attach coaxial antenna cable to the lightning arrestor. 

4.  For a pole mount, use hose clamps to mount the antenna mounting bracket to the pole.  

For a wall mount, attach the antenna bracket to the wall using the four tabs on the bracket.  

5.  If you have a second LoRa antenna, repeat Steps 1 – 4 for the second LoRa antenna.  
6.  Attach the antenna cable to the LoRa (1) connector. If you have a second LoRa antenna,  

connect to the second LoRa (4) connector. 

Requirements 

In addition to the Base Station and included accessories, you will need:  

1 - PoE Injector. For requirements, refer to 

 Conduit IP67 Base Station PoE Application Note 

(S000678). 

1 - Cat 5 or greater Ethernet cable rated for outdoor use. 
1 - Micro SIM (3FF) card for LTE models. MultiTech recommends using a SIM card rated for the climate where the device will be installed. 
1 - 14awg or larger ground wire with a closed loop terminal. For details, go to 

Installing a Ground Wire 

in this document. 

1 - Phillips screwdriver. 
 

Related Accessories

 

PoE injectors, higher gain LoRa antennas, lightning arrestors, and antenna accessories are available through 

www.multitech.com/ip67

Note: 

All antennas can be directly mounted on the Base Station; however, you can mount LoRa antenna(s) up to 5 feet away from 

the Base Station if necessary for your location.

 

Reviews: