MultiVOIP ISDN/BRI Cabling Guide 

Multi-Tech Systems, Inc. 

Introduction 

This guide shows you how to make the cable connections to set up your  

MultiVOIP

®

 ISDN/BRI unit.  See the MultiVOIP 

User Guide

 included on the  

MultiVOIP CD for more information.  The “Quick Start Instructions” chapter shows 
how to get the MultiVOIP ISDN/BRI unit up and running with a basic configuration. 

Safety Warnings 

Lithium Battery Caution 

A lithium battery on the voice/fax channel board provides backup power for the 
timekeeping capability. The battery has an estimated life expectancy of ten 
years. 

When the battery starts to weaken, the date and time may be incorrect.  If the 
battery fails, the board must be sent back to Multi-Tech Systems for battery 
replacement. 

Warning:

  There is danger of explosion if the battery is incorrectly 

replaced. 

Ethernet Ports Caution 

Caution: 

The Ethernet ports and command ports are not designed to 

be connected to a Public Telecommunictaion network.  

Safety Warnings Telecom 

 

Use this product only with UL- and CUL-listed computers (US).  

 

Never install phone wiring during a lightning storm. 

 

Never install a phone jack in a wet location unless the jack is specifically 
designed for wet locations. 

 

Never touch uninsulated phone wires or terminals unless the phone line has 
been disconnected at the network interface. 

 

Use caution when installing or modifying phone lines. 

 

Avoid using a phone during an electrical storm; there is a risk of electrical 
shock from lightning. 

 

Do not use a phone in the vicinity of a gas leak. 

 

To reduce the risk of fire, use only 26 AWG or larger telephone line cord. 

 

This product must be disconnected from power source and telephone 
network interface when servicing. 

Safety Recommendations for Rack Instructions  

 

Ensure proper installation of the MultiVOIP in a closed or multi-unit 
enclosure by following the recommended installation as defined by the 
enclosure manufacturer.  Do not place the MultiVOIP directly on top of other 
equipment or place other equipment directly on top of the MultiVOIP. 

 

If installing the MultiVOIP in a closed or multi-unit enclosure, ensure 
adequate airflow within the rack so that the maximum recommended 
ambient temperature is not exceeded. 

Summary of Contents for MULTIVOIP MVP-410ST

Page 1: ...R MultiVOIP ISDN BRI Voice Fax over IP Networks MVP410ST MVP810ST Cabling Guide ...

Page 2: ...ate Description A 01 12 07 Transition to cabling guide from Quick Start Last QS version was 82100002L Quick setup info transferred to chapter of companion User Guide S000385B and any subsequent Trademarks Multi Tech and the Multi Tech logo are registered trademarks of Multi Tech Systems Inc MultiVOIP is a registered trademark of Multi Tech Systems Inc All other brand and product names mentioned in...

Page 3: ...t only with UL and CUL listed computers US Never install phone wiring during a lightning storm Never install a phone jack in a wet location unless the jack is specifically designed for wet locations Never touch uninsulated phone wires or terminals unless the phone line has been disconnected at the network interface Use caution when installing or modifying phone lines Avoid using a phone during an ...

Page 4: ...dling the load of the MultiVOIP Refer to the power label on the equipment for load requirements Maximum ambient temperature for the MultiVOIP is 60 degrees Celsius 140 F at 20 90 s non condensing relative humidity This equipment should only be installed by properly qualified service personnel Only connect like circuits In other words connect SELV Secondary Extra Low Voltage circuits to SELV circui...

Page 5: ...nd Cable DB25 to DB9 connectors Two rack mount brackets and four mounting screws One printed Cabling Guide One MultiVOIP CD containing software and user documentation FDX LNK XMT RCV XMT RCV XMT RCV XMT XMT RCV XMT Cabling Guide MultiVOIPTM RCV D RCV D ISDN 1 ISDN 2 ISDN 3 ISDN 4 Ethernet Boot Power XMT RCV XMT RCV Ch1 Ch2 Ch3 Ch4 D D Ch5 Ch6 Ch7 Ch8 ...

Page 6: ...MultiVOIP ISDN BRI Cabling Guide 6 Multi Tech Systems Inc Quick Hookup for MVP410ST MVP810ST ...

Page 7: ... between the grounding screw on the MultiVOIP chassis and a permanent earth ground Whether the unit is used in a rack or on a desktop you must verify that the earth ground connection is permanent and reliable In order for the ground connection to be considered permanent the grounding wire must connect to the earth ground of the building s electrical wiring system and the ground connection must use...

Page 8: ...82100250L ...