2. Stop the tractor, switch off the power and engage the parking brake.
3. Check the distance between the outermost rows of the sowing lanes.
The distance between the outermost rows should be 150 mm for the FX300 and
154 mm for the FX400.
4. If the distance is incorrect, adjust the middle markers in accordance with the instructions
in section 5.3.7. Adjusting the middle markers.
6.15. Emptying the hoppers
6.15.1. Emptying the hoppers to the calibration tray
If the hopper is almost empty, the seed or fertiliser is directed to the calibration tray
through the feeders and the tray is emptied. Instructions on performing the calibration
test are provided in section 6.8. Product calibration.
6.15.2. Emptying the hoppers through the coulters
Figure. 6.15.2. - 165. Bottom ap open
1. Open the bottom ap (1) of the seed or fertiliser side for the hopper to be emptied.
Figure. 6.15.2. - 166. Calibration test crank
2. Use the calibration test crank (1) to rotate the feeders.
Emptying can be enhanced with compressed air to blow all seeds and fertiliser
out of the hoppers and feeders.
Operation and maintenance manual
1.00
FX300 and FX400 SeedPilot
131 (208)