IPDA056 User Manual
Version 1.01
Normal Mode
– there will interval between each scanning
Zebra Mode
– there is no interval between each scanning
Meanwhile, there are 2 parameters available to be adjusted:
Time out
– if input 10s and scanning light is moved away from tags and can’t
focus on tags again within 10s, then the scanning light will be off.
Interval
– if the input is 10 ms, then the interval of the continuous scan will be
10ms.
To stop the continuous scan, just uncheck the box of a continuous scan.
UHF
Check the box of the continuous scan, then it will enter continuous scan mode. Before
entering the continuous mode, there are 3 parameters (timeout, interval, output power)
available for you to adjust under this model.
Timeout – if input 10s and scanning light is moved away from tags and can’t
focus on tags again within 10s, then the scanning light will be off.
Interval – if the input is 10 ms, then the interval of the continuous scan will be
10ms.
Output power – can choose from 1 to 30 dBm, the reading performance is in
proportion to the output power, which means, the higher you set output power,
the better reading performance you will get.
You can also choose to read the EPC or TID of the RFID tags by selecting the EPC or
TID checkbox.