Operation:

Before operating, please ensure the installation and wire connection.

1. Operating by Remote control

Within 6M (60°C), direct the Remote Controller to the Receiver. Press "ON
/ OFF" to start normal air and then press “Warm” to start warm air.
When in normal air, press “ON/OFF” to shutdown the operation. If in warm
air, press “ON/OFF”, the air curtain will be in delay condition for 3 minutes
(Red indicated lamp glimmering) and then shut down.

2. Operating by Receiver directly

Push “Warm/Normal/Off” button to choose what your desired. When push
“Off”, the air curtain will be in delay condition for 3 minutes and then auto-
matic shut down.

Maintenance and repair:

1. Unplug the unit from any power source prior checking or maintenance.

2. Keep electric motor or other parts away from moisture to avoid short cir-

cuit.

3. Regular checking and maintenance is recommended, clean all the dust

off. Simply damp with mild detergent by a cloth for cleaning.

4. Detach the unit only by professionals.

Specifications:

Model

MU-ECO

Part Num.

Length

Power

(W)

Air

speed

(m / s)

Noise level

(dB)

Weight

(kg)

Normal

Warm

09/6R
09/6R3 ph

EC 06 414
EC 06 417

900 mm

160

6160

7

55

20.2

12/8R
12/8R3 ph

EC 06 415
EC 06 418

1200

mm

230

7430

57

23.2

15/8R
15/8R3 ph

EC 06 416
EC 06 419

1500

mm

300

9300

59

29.0

NOTE: Rated voltage and frequency are stated as per rating label.

7

Summary of Contents for MU-ECO Series

Page 1: ...CORTINA DE AIRE con calefacción Serie MU ECO MUND CLIMA ES EN ...

Page 2: ...or a 50 C 3 La humedad relativa 95 2 Ha de instalarse en un lugar sólido a efectos evitar posibles vibraciones El evitar vibraciones puede evitar ruidos innecesarios además de evitar si tuaciones peligrosas Las cortinas de aire estan diseñadas para ser insta ladas en interior a una altura minima de 2 3 metros desde el suelo 3 Pueden instalarse diferentes unidades contiguas cuando nos hayamos ante ...

Page 3: ...Dimensiones Dimensiones en mm Longitud A L1 L2 900 mm 900 270 300 1200 mm 1200 420 1500 mm 1500 570 3 ...

Page 4: ...ndo pulse el botón OFF la cortina se apa gará a los 3 minutos Mantenimiento y reparación 1 Desconecte la unidad de la red eléctrica antes de comenzar 2 Mantenga las partes eléctricas lo más aisladas posibles a efectos de evi tar posibles cortocircuitos 3 Es aconsejable el mantenimiento y la inspección de la unidad limpie la suciedad del mismo Simplemente lávelo con detergente neutro y un tra po de...

Page 5: ...e to avoid vibrations when machine is running as well as for safety reason unnecessary noise caused by vibration can be prevented Air Curtains are used for indoor purpose and should be insta lled at the height of at least 2 3 m above the ground 3 Several units can be mounted next to each other when wider openings oc cur Under such condition a narrow space in between 20 50mm for each two units may ...

Page 6: ...Diagram Dimensions in mm Body length A L1 L2 900 mm 900 270 300 1200 mm 1200 420 1500 mm 1500 570 6 ...

Page 7: ... in delay condition for 3 minutes and then auto matic shut down Maintenance and repair 1 Unplug the unit from any power source prior checking or maintenance 2 Keep electric motor or other parts away from moisture to avoid short cir cuit 3 Regular checking and maintenance is recommended clean all the dust off Simply damp with mild detergent by a cloth for cleaning 4 Detach the unit only by professi...

Page 8: ...es Gráficas 10 12 Tel 96 511 23 42 Fax 96 511 57 34 03008 Alicante Av Enrique Gimeno 24 Pol C Transporte CP 12006 Tel 96 424 72 11 Fax 96 424 72 03 Juan Bautista Escudero 219 C Pol Las Quemadas CP 14014 Tel 957 32 27 30 Fax 957 32 26 26 Pol Juncaril c Lanjarón 10 Tel 958 49 10 50 Fax 958 49 10 51 18220 Albolote Granada P Olivares Cazalilla p 527 Tel 953 28 03 01 Fax 953 28 03 46 23009 Jaén Pol Seg...

Reviews: