background image

 

A151-VR

Page 6 of 11

Date: 

10/28/2020

7021-020-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

2. 

Air within the drinking fountain system or the structure supply piping will cause an irregular bubbler outlet 

stream until purged out by incoming water. Covering the bubbler with a clean cup (or similar object) is 
recommended when first activating drinking fountain to prevent excessive splashing. Depress front push pad 
until steady water stream is achieved.

3. 

If water flow requires adjustment, insert a slotted narrow blade screwdriver in the hole centered on the 

underside of the fixture in the knee clearance area up to the flow regulator. Turning clockwise will increase 
flow and turning counterclockwise will decrease flow.

1. 

Before connecting power supply, but after thoroughly flushing the supply line, turn on building water supply 

and check all connections for leaks.

4. 

Recheck all water connections with water flowing through system.

3. Provide mounting surface, adequate to support the fixture and loads on the fixture.

5. Completely flush water supply lines of all foreign debris, before connecting to the fixture.

 1.  Water Supply Service Stop Valve and Water Connections to be supplied by others in accordance with local 

codes.

 2.  Waste is 1-1/4” Outer Diameter. Drinking Fountain water inlet is 3/8” Outer Diameter copper tube. Bottle 

Filler water inlet is 3/8” Outer Diameter copper tube. Water line by others.

 3.  Completely flush supply lines of all foreign debris before connecting to fixture. Optional Water Filter (WF1), is 

available should any problems with taste, odor, color, or sediment arise from the water supply.

IMPORTANT:

4.  All burrs must be removed from outside of cut tubes before inserting into strainer or other components.

 5. 

Per UPC 609.10-All building water supply systems in which quick acting valves are installed shall be 
provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the 
valve. These pressure-absorbing devices shall be approved mechanical devices. Water pressure-absorbing 
devices shall be installed as close as possible to the quick closing valve.

1. Read all installation instructions carefully, before proceeding.
2. Carefully remove all fixture components  from packaging, preventing scratching or damage. Inspect fixture and 

all parts from damages and all parts that are bolted on.

PRIOR TO INSTALLATION:

4. Provide rough-ins as shown on the roughing-in and dimensional drawing, including water supply, drain pipe 

and gravel drain well. (See rough-in details)

1. Insert mounting frame into the rough-in block out and secure using 1/4”-20 UNC mounting hardware (Provided 

by Others).

2. Hang trim panel on mounting frame. Note: The included 1” brackets do not get used with this installation and 

the plastic spacers are typically not required and can be discarded.

3. Install the four threaded studs into the Wall Mounting Frame
4. Remove the drinking fountain top by taking out the drain screw and lifting at the front while pulling forward. 

Disconnect bubbler tube. Set top aside in a safe place where it will not be damaged. Place the screw in a 
secure location where it will not be lost.

5. Slide Fixture over studs and secure with nuts and washers.
6. Assemble P-trap to drain adapter and then assemble to unit with Phillips head screws.
7. Make-up 1-1/4” outer diameter waste connection.
8. After thoroughly flushing the 3/8” outer diameter supply line, connect water supply to the 3-way divider 

assembly. From the 3-way divider assembly, connect to drinking fountain bubbler.

9. Place drain gasket on drain adapter. Reconnect bubbler tube. Reassemble top to unit by engaging back clip 

and securing with screw.

DRINKING FOUNTAIN INSTALLATION:

DRINKING FOUNTAIN START UP:

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Summary of Contents for A151-VR Series

Page 1: ...ing or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of a...

Page 2: ...nsions as required to comply with federal state and local codes A151 VR Page 2 of 11 Date 10 28 2020 7021 020 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS GENERAL NOTES 1 ALL DIMENSIO...

Page 3: ...tor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of SUPPLIED WALL MOUNTING PLATE 1 1 1 4 OD WASTE OUTLET 2 3 8 NCT SUPPLY INLET 3 CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS 2 10 3 1 21 2 3 8 271 4 295 8 28 33 2 ...

Page 4: ...CHALK LINE TO LOCATE BOTTOM MOUNTING HOLES 3 REFERENCE DISCHARGE HEIGHT REQUIREMENTS FOR YOUR MODEL AND FACILITY TO DETERMINE CORRECT HEIGHT AT FINISHED FLOOR AFF AFTER POSITIONING PLATE CORRECTLY FIX PLATE TO WALL USING APPROPRIATE INSTALLER PROVIDED ANCHORING HARDWARE 4 MAKE UP APPROPRIATE SUPPLY 5 AND WASTE 6 ROUGHS THROUGH MOUNTING PLATE OPENINGS LOCATE 5 16 THREADED STUDS MOUNTING HARDWARE AN...

Page 5: ...of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of WATER TUBING CONNECTIONS CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS PE Tubing Mounting Plate 3 8 O D Copper Inlet ...

Page 6: ...ter supply systems in which quick acting valves are installed shall be provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve These pressure absorbing devices shall be approved mechanical devices Water pressure absorbing devices shall be installed as close as possible to the quick closing valve 1 Read all installation instructions carefully...

Page 7: ...TTOM FLANGES 2 ARE AGAINST FINISHED WALL SECURE TO WALL FROM THE TOP SIDES AND BOTTOM USING INSTALLER PROVIDED HARDWARE 3 C INSTALL TRIM PANEL 4 BY ENGAGING OVER JOGGLE 5 ON TOP OF FRAME 1 SEE ENGAGEMENT DETAIL D ASSEMBLY OF DRINKING FOUNTAIN THROUGH TRIM PANEL 4 INTO MOUNTING FRAME 1 HELPS SECURE TRIM PANEL 4 INTO ONTO WALL 4 5 ENGAGEMENT DETAIL NOTE TRIM PANEL FIXTURE MOUNTING POINTS 6 DIFFER TO...

Page 8: ...HE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be s...

Page 9: ...er Thermostat The water temperature can be adjusted using a slotted screwdriver and turning clockwise to make colder and counterclockwise to make warmer A151 VR Page 9 of 11 Date 10 28 2020 7021 020 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 3 Periodically remove fountain top and clean out in l...

Page 10: ...t Ports on the Cartridge with the Ports in the Valve Body 1 Strainer Plug must be removed before Cartridge replacement and Strainer maintenance no need to turn the water off at the Angle Stop Some residual water will drainduring Plug removal 2 Clean Strainer as needed using clean water NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW Push in Fittings Strainer Plug Removal of P E Tubing from...

Page 11: ...r 9 7003 193 000 Spring Pushbutton Return 2 0116 016 000 10 32 x 3 8 Phillips Truss Head Screw 10 7003 196 199 Pushbutton Chrome 3 7000 006 000 Flat Drain Adapter Gasket 11 7003 197 199 Escutcheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 0161 062 000 6 32 x 1 2 Phillips Flat Head Screw 5 0152 010 000 10 32 x 1 Hex Flat Head Screw 13 0124 055 000 8 x 3 4 Phillips Round Head Screw 6A 7000 012 001 St...