background image

 

g.  Flow control in solenoid valve outlet elbow clogged remove & clean.

 

h.  No power to transformer connections, loose or wires cut.

 

f.  Check flow adjustment. See start up note #3.

 

a.  Open fixture. Loosen nuts holding valve bracket assembly to bottom of fixture but, do not remove. Move 

complete valve bracket assembly further back from the front push pad and tighten to lock in place.

 

b.  Replace valve cartridge.

3. WATER DRIPS OR WILL NOT SHUT OFF:

TROUBLE SHOOTING:

 

c.   Bubbler Stream - Bubbler can be rotated slightly to direct the stream backwards or forwards. Adjust the 

stream to minimize splashing. Splashing may occur from bubbler stream if the unit is not level. Shim lower 
mounting point, if necessary, to level chiller.

2. RESTRICTED OR NO WATER FLOW:

 

a.  Ensure water supply service stop valve is fully open.

 

b.  Verify minimum 20 psig supply line flow pressure.

 

c.  Check for twists or kinks in outlet tubing.

 

a.  Cartridge – The water flow can be adjusted using a slotted narrow blade screwdriver and turning 

clockwise to increase flow and counterclockwise to decrease flow.

1. ADJUSTMENTS:

 

d.  Check the water inlet “Y” strainer. Sediment from the main supply can get trapped in the screen along 

with installation materials such as pipe dope and flux. The screen should be cleaned and checked on a 
regular basis and replace if needed.

 

e.  The cartridge valve located in the water control assembly or bubbler can also become clogged with 

foreign material. The cartridge valve can only be replaced and not repaired.

 

b.  Cold Water Thermostat – The water temperature can be adjusted using a slotted screwdriver and turning 

clockwise to make colder and counterclockwise to make warmer.

 

A151-VR

Page 9 of 11

Date: 

10/28/2020

7021-020-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

3. 

Periodically remove fountain top and clean out in-line strainer.

3.    Stainless steel should be kept clean at all times. If a coating of stainless steel cleaner/polish is maintained, 

stainless steel surfaces will retain their new, clean, polished appearance indefinitely.

2.    If there are stubborn spots or if you wish to treat a scratch, synthetic abrasive general  purpose pads   such as   

scotch brite are recommended.

For Stainless steel units:

1.    To Remove water spots or rust spots, stainless steel cleaner/polish on a cloth is  recommended.

CLEANING & MAINTENANCE GUIDE:

1. 

Motors have lifetime lubrication and do not require scheduled maintenance.

2. 

Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it 

will cycle on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air 
hose or brush the condenser fins and cabinet ventilation louvers. In environments where dirt and dust is 
more prevalent, clean more frequently.

4. 

Periodically remove access panel of cooler and clean out inline “Y’’ strainer

For Powder coated units:

 Units should be cleaned using a mild soap solution with a sponge or cotton cloth. 

Wipe down surfaces then rinse with clean water.

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Summary of Contents for A151-VR Series

Page 1: ...ing or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of a...

Page 2: ...nsions as required to comply with federal state and local codes A151 VR Page 2 of 11 Date 10 28 2020 7021 020 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS GENERAL NOTES 1 ALL DIMENSIO...

Page 3: ...tor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of SUPPLIED WALL MOUNTING PLATE 1 1 1 4 OD WASTE OUTLET 2 3 8 NCT SUPPLY INLET 3 CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS 2 10 3 1 21 2 3 8 271 4 295 8 28 33 2 ...

Page 4: ...CHALK LINE TO LOCATE BOTTOM MOUNTING HOLES 3 REFERENCE DISCHARGE HEIGHT REQUIREMENTS FOR YOUR MODEL AND FACILITY TO DETERMINE CORRECT HEIGHT AT FINISHED FLOOR AFF AFTER POSITIONING PLATE CORRECTLY FIX PLATE TO WALL USING APPROPRIATE INSTALLER PROVIDED ANCHORING HARDWARE 4 MAKE UP APPROPRIATE SUPPLY 5 AND WASTE 6 ROUGHS THROUGH MOUNTING PLATE OPENINGS LOCATE 5 16 THREADED STUDS MOUNTING HARDWARE AN...

Page 5: ...of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of WATER TUBING CONNECTIONS CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS PE Tubing Mounting Plate 3 8 O D Copper Inlet ...

Page 6: ...ter supply systems in which quick acting valves are installed shall be provided with devices to absorb the hammer caused by high pressure resulting from the quick closing of the valve These pressure absorbing devices shall be approved mechanical devices Water pressure absorbing devices shall be installed as close as possible to the quick closing valve 1 Read all installation instructions carefully...

Page 7: ...TTOM FLANGES 2 ARE AGAINST FINISHED WALL SECURE TO WALL FROM THE TOP SIDES AND BOTTOM USING INSTALLER PROVIDED HARDWARE 3 C INSTALL TRIM PANEL 4 BY ENGAGING OVER JOGGLE 5 ON TOP OF FRAME 1 SEE ENGAGEMENT DETAIL D ASSEMBLY OF DRINKING FOUNTAIN THROUGH TRIM PANEL 4 INTO MOUNTING FRAME 1 HELPS SECURE TRIM PANEL 4 INTO ONTO WALL 4 5 ENGAGEMENT DETAIL NOTE TRIM PANEL FIXTURE MOUNTING POINTS 6 DIFFER TO...

Page 8: ...HE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be s...

Page 9: ...er Thermostat The water temperature can be adjusted using a slotted screwdriver and turning clockwise to make colder and counterclockwise to make warmer A151 VR Page 9 of 11 Date 10 28 2020 7021 020 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of 3 Periodically remove fountain top and clean out in l...

Page 10: ...t Ports on the Cartridge with the Ports in the Valve Body 1 Strainer Plug must be removed before Cartridge replacement and Strainer maintenance no need to turn the water off at the Angle Stop Some residual water will drainduring Plug removal 2 Clean Strainer as needed using clean water NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW Push in Fittings Strainer Plug Removal of P E Tubing from...

Page 11: ...r 9 7003 193 000 Spring Pushbutton Return 2 0116 016 000 10 32 x 3 8 Phillips Truss Head Screw 10 7003 196 199 Pushbutton Chrome 3 7000 006 000 Flat Drain Adapter Gasket 11 7003 197 199 Escutcheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 0161 062 000 6 32 x 1 2 Phillips Flat Head Screw 5 0152 010 000 10 32 x 1 Hex Flat Head Screw 13 0124 055 000 8 x 3 4 Phillips Round Head Screw 6A 7000 012 001 St...