background image

A152.8-BF4 Series

Rounded Box Chilled Barrier Free Wall Mount Bi-Level

Drinking Fountain w/ Sensor Activated Bottle Filler

 

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly 
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship 
under normal use for an additional four (4) years from the end of the one (1) year period described above.

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

LIMITED WARRANTY - UNITED STATES & CANADA

LIMITED EXPORT WARRANTY - 

One year on parts only. 

Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free 
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) 
months after the date of shipment from the factory, whichever comes first. 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

COMPLIES 

WITH

Test rating conditions are
compliant with ARI 1010.

Federal
Public Law
111-380 
(No Lead)

Member of

 

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

www.murdockmfg.com

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

7020-949-001 

      

Date: 07/18/18

Summary of Contents for A152 8-BF4 Series

Page 1: ...mplied Product maintenance instructions are issued with each unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site during construction and must be properly maintained after the water has been introduced into the water cooler or drinking fountain or Murdock s limited warranty is void...

Page 2: ...with Bottle Filler NOTES Dimensions shown for Adult ADA compliant installation For Child ADA compliant parallel approach installation decrease height of installation by 3 inches Provide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S...

Page 3: ...ERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8 BF4 Page 3 of 32 Revised 07 18 18 7020 949 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of General Notes 1 All dimensions are in inches 2 Dimensions shown are for recommended adult height Adjust vertica...

Page 4: ...e as required Adjust vertical dimensions as required to comply with federal state and local codes A152408S BF4 Refrigerated Wall Mounted Drinking Fountain Inlet Outlet Rough Ins Note There are no mounting changes to be made for SO models 16 8 38 C L 2 1 2 TYP 35 295 8 3 8 TYP 501 2 BLOCKOUT 561 4 301 4 BLOCKOUT 31 2 1 2 3 4 General Notes 1 Dimension indicated with is for 33 drinking fountain disch...

Page 5: ...on is always on the right hand side of the shelf Installation Instructions A Provide 30 1 4 wide x 50 1 2 tall wall opening at appropriate height Provide structural support around inside of the opening for frame anchoring B Carefully remove Bi Level Mounting Frame 1 chiller mounting frame 2 panel anchoring clips 3 and screws 4 from packaging preventing damage C Center both frames within wall openi...

Page 6: ... inlet is 3 8 Outer Diameter copper tube Water line by others from in wall chiller to drinking fountain must have adequate insulation 4 Completely flush supply lines of all foreign debris before connecting to fixture Water cooler designed to not cause problems with taste odor color or sediment Optional Water Filter WF1 is available should any of these problems arise from the water supply 6 All bur...

Page 7: ...ste connection 3 FOR BF4 ONLY Make up power connections to the ground neutral hot within the electrical box 2 Place the Chiller Unit onto the basepan of the frame assembly 3 Hang upper trim panel on mounting frame Note The included 1 brackets do not get used with this installation and the plastic spacers are typically not required and can be discarded 8 Make up 1 1 4 outer diameter waste connectio...

Page 8: ...ling fan to ensure proper clearance and free fan action ŸSENSOR OPERATED Hold container to be filled just below the sensor in the center of the filler spout and then move the container upward and water flow will start automatically When the container is almost filled lower the container below the sensor until the water stops flowing See label on the bottle filler 1 Air within the bottle filler sys...

Page 9: ... City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of WATER TUBING CONNECTIONS NOTE Insulation on all water tubes not shown all PE water tubes are insulated 3 8 O D Copper Inlet 3 8 O D Copper Outlet Electrical Knockout Chiller Assembly Detail Thermal Adjustment PE Tubing PE Tubing Fill Spout 9 12VDC Solenoid Valve Solenoid Valve Outlet Elb...

Page 10: ...53 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of ITEM PART NUMBER DESCRIPTION 1 0250 006 000 10 x 5 8 Phillips Truss Head Screw 2 7014 035 199 Water Filter Bracket 3 0124 031 000 8 x 3 8 Hex Washer Head Screw 4 1895 709 000 Elbow 1 4 Push In x 1 4 Stem 5 7012 311 000 WF1 Filter 1500 Gallon 6 2169 000 000 Tubing 1 4 O D LLDPE Blue 7 7012 055 000 Foam Pipe Insulation FILTER MOUN...

Page 11: ...0 www murdockmfg com Member of ITEM PART NUMBER DESCRIPTION 1 0250 006 000 10 x 5 8 Phillips Truss Head Screw 2 7014 055 199 Bracket Dual Filter Mount 3 0124 031 000 8 x 3 8 Hex Washer Head Screw 4 1895 709 000 Elbow 1 4 Push In x 1 4 Stem 5 7012 311 000 WF1 Filter 1500 Gallon 6 2169 000 000 Tubing 1 4 O D LLDPE Blue 7 7012 055 000 Foam Pipe Insulation Not Show n 8 1895 710 000 Untion Tee 1 4 Push...

Page 12: ...e provided by others Turn valve knob 1 4 turn clockwise to close OPTIONAL WF1 WATER FILTER INSTALLATION 2 With the filter assembly secured on the unit hold before re mounting panel assembly to fixture the cap firmly turn the replaceable cartridge filter counterclockwise to remove clockwise to secure 1 Remove panel assembly this allows access to the FILTER CARTRIDGE REPLACEMENT 3 Remove and replace...

Page 13: ...OOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS 1B For Reverse Bi Level unit will be reversed NOTE Plug in power is a standard feature 1A Plug In Operation Plug transformer provided into GFCI protected electrical service used by the semi recessed bottle filler Plug in transformer to power supply and connect to red sensor wire ELECTRICAL INSTALLATION 9 ...

Page 14: ...UNTER ADJUSTING RESETTING INSTRUCTIONS Bottle Counting Function The software applies a flow volume of approximately 16 9 fl oz volume in standard size plastic water bottle to each bottle counted If the flow volume is less than 16 9 fl oz there will be no count but the volume will accumulate so that part way through the next cycle the total bottle count will change NOTE Bottle Counter Has Multiple ...

Page 15: ...lter flow volume is reached FLTR NO means that there is no filter in the system and a REPLACE FILTER alert WILL NOT APPEAR on the display Release button when the option required is on the display Filter Yes or No NOTE This Function only applies if the system as a filter Replace old filter with new filter Depress the Reset Mode selection button for 2 SECONDS The REPLACE FILTER will no longer appear...

Page 16: ... R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS OPTIONAL BCD BOTTLE COUNTER DISPLAY See the following page for models with BCD Bottle Counter Display A132 BF4 BCD BOTTLE FILLER BOTTLE COUNTER CONNECTIONS Solenoid Connection Power Supply Connection Black Cables Sensor Connection Black Red Cables Sensor Connection Tra...

Page 17: ...re Tube should not come free from the fitting Water test the connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE To disconnect the tube from the fitting ensure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE...

Page 18: ...igeration system and the water chiller must be checked by an authorized service company a The most common cause for a water chiller to run without producing cold water is a loss of refrigerant The water chiller must be taken to a certified refrigerant technician for repairs a Check to make sure the fan blade is rotating freely c A restriction or moisture in the system will also cause intermittent ...

Page 19: ...r or two holes in convolution of the water diaphragm Remove and clean 1 Motors have lifetime lubrication and do not require scheduled maintenance 2 Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it will cycle on and off with no cold water coming out of bubbler Periodically clean with vacuum cleaner air hose or brush the condenser fins an...

Page 20: ... PART NUMBER DESCRIPTION 1 7000 005 199 Drain Adapter 10 0308 009 000 Nylon Insert Locknut 2 0116 016 000 Phillips Truss Head Screw 11 0331 004 000 Flat Washer 3 7000 006 000 Flat Drain Adapter Gasket 12 7001 008 001 Valve Activation Assembly 4 7000 015 000 1 1 4 OD P Trap 13 0341 100 000 Wire Clip 5 7000 021 001 Y Strainer 14 7000 100 199 Black Delrin Shaft 6 0152 010 000 10 32 x 1 2 Hex Flat Hea...

Page 21: ... PART NUMBER DESCRIPTION 1 7000 005 199 Drain Adapter 10 0308 009 000 Nylon Insert Locknut 2 0116 016 000 Phillips Truss Head Screw 11 0331 004 000 Flat Washer 3 7000 006 000 Flat Drain Adapter Gasket 12 7001 008 001 Valve Activation Assembly 4 7000 015 000 1 1 4 OD P Trap 13 0341 100 000 Wire Clip 5 7000 021 001 Y Strainer 14 7000 100 199 Black Delrin Shaft 6 0152 010 000 10 32 x 1 2 Hex Flat Hea...

Page 22: ...RDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Repairs must be made with Murdock Manufacturing parts only Please order through your local representative or distributor The phone number to locate your local representative is 1 800 591 9360 37A 45 32 33 34 35 46 47 40 44 43 42 41 39 40 38 36 10 11 12 13 24...

Page 23: ... 2 Stainless Steel Truss Head Screw 17 7013 238 199 Y Strainer Clamp 18 7013 235 001 3 Way Divider Assembly 1 4 x 1 4 19 0112 021 000 10 32 x 1 2 Stainless Steel Button Head Hex Screw 20 7013 231 199 3 Way Divider Bracket Assembly 1 4 x 1 4 21 0331 042 000 6 Helical Spring Lock Washer 22 0302 011 000 6 32 UNC Stainless Steel Hex Nut 23 7000 245 000 Back Panel Spacer 24 7014 150 001 Frame Assembly ...

Reviews: