1. With drinking fountain installed, connect water supply line from multi-line “Y” strainer assembly to bottle filler.
4. Test for leaks and proper operation, and then install the bottle filler panel using the water filler bracket and
secure the bottle filler by tightening the screws under the bottle filler.
4. Install the four threaded studs into the Wall Mounting Frame
5. Remove the drinking fountain top by taking out the drain screw and lifting at the front while pulling forward.
Disconnect bubbler tube. Set top aside in a safe place where it will not be damaged. Place the screw in a
secure location where it will not be lost.
6. Slide Fixture over studs and secure with nuts and washers.
1. Insert mounting frame into the rough-in block out and secure using 1/4”-20 UNC mounting hardware (Provided
by Others).
10. Place drain gasket on drain adapter. Reconnect bubbler tube. Reassemble top to unit by engaging back clip
and securing with screw.
2. Loosen slip nuts to orientate P-trap to desired direction then tighten slip nuts and make up 1-1/4” O.D. waste
connection.
3.
FOR -BF4 ONLY
Make up power connections to the ground, neutral & hot within the electrical box.
2. Place the Chiller Unit onto the basepan of the frame assembly.
3. Hang upper trim panel on mounting frame. Note: The included 1” brackets do not get used with this installation
and the plastic spacers are typically not required and can be discarded.
8. Make-up 1-1/4” outer diameter waste connection.
9. After thoroughly flushing the 3/8” outer diameter supply line, connect water supply to in-wall chiller and provide
connection from chiller to ‘the multi-line “Y” strainer assembly. From multi-line “Y” strainer assembly, connect to
drinking fountain bubbler.
7. Assemble P-trap to drain adapter and then assemble to unit with Phillips head screws.
DRINKING FOUNTAIN INSTALLATION:
BOTTLE FILLER INSTALLATION:
NOTE: BEFORE PERFORMING STEP 4, REFER TO ELECTRICAL INSTALLATION.
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
A152.8-BF4
Page 7 of 32
Revised:
07/18/18
7020-949-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of