background image

A152.8FG Series

Barrier Free, Wall Mounted Electric Drinking Fountain 

 

A152408F-FG / A152408S-FG

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

 

 

 

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free 
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) 
months after the date of shipment from the factory, whichever comes first. 

LIMITED WARRANTY - UNITED STATES & CANADA

LIMITED EXPORT WARRANTY - 

One year on parts only. 

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly 
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship 
under normal use for an additional four (4) years from the end of the one (1) year period described above. 

COMPLIES 

WITH

7020-006-001 

      

Date: 07/18/18

Test rating conditions are
compliant with ARI 1010.

Federal
Public Law
111-380 
(No Lead)

Member of

 

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

www.murdockmfg.com

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

Summary of Contents for A152.8FG Series

Page 1: ... Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each unit and disregard or non complian...

Page 2: ...compliant parallel approach installation decrease height of installation by 3 inches Provide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8FG Pa...

Page 3: ...T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8FG Page 3 of 9 Revised 07 18 18 7020 006 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of FINISHED FLOOR GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NEC...

Page 4: ...lied by installer be insulated appropriately to prevent excessive condensation 6 All burrs must be removed from outside of cut tubes before inserting into strainer or other components 8 This unit must be grounded per the requirements of applicable electrical codes 12 Per UPC 609 10 All building water supply systems in which quick acting valves are installed shall be provided with devices to absorb...

Page 5: ...6 Slide fixture over studs and secure with nuts and washers 2 5 Remove the drinking fountain bottom access panels 1 Set the access panels aside in a safe place where they will not be damaged and place the screws in a secure location where they will not be lost I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E ...

Page 6: ... begins to function TROUBLE SHOOTING IMPORTANT BEFORE MAKING ANY OF THE REPAIRS LISTED MAKE SURE THE WATER SUPPLY VALVE IS SHUT OFF a Cartridge The water flow can be adjusted using a slotted narrow blade screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow b Cold Water Thermostat The water temperature can be adjusted using a slotted screwdriver and turning clock...

Page 7: ... be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner c An incorrect refrigerant charge restriction or defective compressor not pumping will also cause the compressor to run without producing cold water All these signs indicate a problem within the refrigeration system and the water chiller must be checked by an authorized service company 5 Noisy Operation 4 Compres...

Page 8: ...n fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep INSERTING THE TUBE COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N T...

Page 9: ...ter P Trap 9 7000 068 001 Retaining Ring Button Assembly 4 7000 021 001 Y Strainer 10 7000 069 001 Valve Cartridge With Foam Washer 5 7000 005 199 Drain Adapter 11 7000 065 001 Recessed Pushbutton Valve Assembly 6 7000 006 000 Flat Drain Adapter Gasket 12 7003 093 001 Flow Restrictor Low Flow Bubbler Only 7 0152 010 000 Center Reject Allen Flat Head Screw 6 5 4 3 2 1 6 9 10 11 8B 8A 12 NOTE Flow R...

Reviews: