A152408S-FG & A152408F-FG

 Refrigerated Reverse Bi-Level Wall Mounted Drinking Fountain

Prior to roughing consult with local, state, and federal codes for proper compliance

ROUGHING-IN AND DIMENSIONAL DRAWING

NOTES:

 Dimensions shown for Adult ADA compliant installation. For Child ADA compliant parallel 

approach installation, decrease height of installation by 3 inches. Provide clear floor space as required. 
Adjust vertical dimensions as required to comply with federal, state, and local codes.

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A152.8FG

Page 3 of 9

Revised: 

07/18/18

7020-006-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

FINISHED FLOOR

 GENERAL NOTES:
 1. ALL DIMENSIONS ARE IN INCHES [MM]

*2. DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL

DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES

 3. WATER LINE FROM CHILLER TO FOUNTAIN SHOULD BE COVERED WITH SPONGE FOAM

RUBBER OR ICE WATER TYPE INSULATION OF ADEQUATE THICKNESS

1

3
8

"

4

1
2

"

*33

1
2

"

SUPPLY STOP

VALVE BY

OTHERS

19

1
4

"

20"

30

1
4

"

WALL

OPENING

3/8" OD SUPPLY

INLET

11"

WALL

OPENING

3/8" OD
COPPER
TUBING

SUPPLIED MTG

FRAME

38

3
8

"

WALL

OPENING

32"

2"

*6

1
4

"

*38

3
8

"

WASTE OUTLET

FOR 1-1/4" P-TRAP

16"

2"

1
4

"

*30"

1
4

"

8

3
8

"

Summary of Contents for A152.8FG Series

Page 1: ... Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each unit and disregard or non complian...

Page 2: ...compliant parallel approach installation decrease height of installation by 3 inches Provide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8FG Pa...

Page 3: ...T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8FG Page 3 of 9 Revised 07 18 18 7020 006 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of FINISHED FLOOR GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NEC...

Page 4: ...lied by installer be insulated appropriately to prevent excessive condensation 6 All burrs must be removed from outside of cut tubes before inserting into strainer or other components 8 This unit must be grounded per the requirements of applicable electrical codes 12 Per UPC 609 10 All building water supply systems in which quick acting valves are installed shall be provided with devices to absorb...

Page 5: ...6 Slide fixture over studs and secure with nuts and washers 2 5 Remove the drinking fountain bottom access panels 1 Set the access panels aside in a safe place where they will not be damaged and place the screws in a secure location where they will not be lost I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E ...

Page 6: ... begins to function TROUBLE SHOOTING IMPORTANT BEFORE MAKING ANY OF THE REPAIRS LISTED MAKE SURE THE WATER SUPPLY VALVE IS SHUT OFF a Cartridge The water flow can be adjusted using a slotted narrow blade screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow b Cold Water Thermostat The water temperature can be adjusted using a slotted screwdriver and turning clock...

Page 7: ... be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner c An incorrect refrigerant charge restriction or defective compressor not pumping will also cause the compressor to run without producing cold water All these signs indicate a problem within the refrigeration system and the water chiller must be checked by an authorized service company 5 Noisy Operation 4 Compres...

Page 8: ...n fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep INSERTING THE TUBE COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N T...

Page 9: ...ter P Trap 9 7000 068 001 Retaining Ring Button Assembly 4 7000 021 001 Y Strainer 10 7000 069 001 Valve Cartridge With Foam Washer 5 7000 005 199 Drain Adapter 11 7000 065 001 Recessed Pushbutton Valve Assembly 6 7000 006 000 Flat Drain Adapter Gasket 12 7003 093 001 Flow Restrictor Low Flow Bubbler Only 7 0152 010 000 Center Reject Allen Flat Head Screw 6 5 4 3 2 1 6 9 10 11 8B 8A 12 NOTE Flow R...

Reviews: