CLEANING & MAINTENANCE GUIDE:
1.
Motors have lifetime lubrication and do not require scheduled maintenance.
2.
Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it
will cycle on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air
hose or brush the condenser fins and cabinet ventilation louvers. In environments where dirt and dust is
more prevalent, clean more frequently.
3.
Periodically remove fountain top and clean out in-line strainer.
4.
Periodically remove access panel of cooler and clean out inline “Y’’ strainer
For Powder coated units:
Units should be cleaned using a mild soap solution with a sponge or cotton cloth.
Wipe down surfaces then rinse with clean water.
For Stainless steel units:
1.
To Remove water spots or rust spots, stainless steel cleaner/polish on a cloth is
recommended.
2.
If there are stubborn spots or if you wish to treat a scratch, using synthetic abrasive general
purpose pads, such as Scotch-Brite™, are recommended.
3.
Apply stainless steel cleaner/ polish to the synthetic abrasive pads and carefully rub the
panel with the grain.
4.
DO NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will
void the Murdock warranty. DO NOT use abrasives on powder coated units.
5.
Stainless steel should be kept clean at all times. If a coating of stainless steel cleaner/
polish is maintained, stainless steel surfaces will retain their new, clean, polished
appearance indefinitely.
DRINKING FOUNTAIN CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE
Note: Use the universal maintenance tool to perform the following:
1.
Strainer plug must be removed before cartridge replacement and strainer maintenance (no need to turn the
water off at the angle stop). Some residual water will drain during plug removal.
2.
Clean strainer as needed using clean water.
3.
Cartridge replacement - insert diamond end of the universal tool into pushbutton, rotate 90 degrees and pull
firmly to remove the button. Remove cartridge retaining nut . Remove and replace cartridge. When replacing
cartridge be sure to align the inlet and outlet ports on the cartridge with the ports in the valve body.
—
NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
A152-BF4
Page 18 of 22
Revised:
02/02/18
7020-951-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
2
1
3
CARTRIDGE VALVE PARTS BREAKDOWN
3
7000-053-199
Jam Nut
2
7000-060-000
Flow Regulator Cartridge (0.5 GPM)
1
7000-050-001
Valve Cartridge Assembly
ITEM PART NUMBER