background image

A171.8

 Series

FGVR

Barrier Free, 14 Gage Stainless Steel, Enhanced 

Vandal Resistance, Wall Mounted Water Cooler 

 

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

 

 

 

 

 

COMPLIES 

WITH

7020-927-001 

      

Date: 07/18/18

Test rating conditions are
compliant with ARI 1010.

Federal
Public Law
111-380 
(No Lead)

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 WATER COOLERS

 

Member of

 

MURDOCK

15125 Proctor Ave.

City of Industry, CA

91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

 

www.murdockmfg.com

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly 
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship 
under normal use for an additional four (4) years from the end of the one (1) year period described above.

LIMITED EXPORT WARRANTY - 

One year on parts only. 

LIMITED WARRANTY - UNITED STATES & CANADA

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free 
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) 
months after the date of shipment from the factory, whichever comes first. 

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

Summary of Contents for A171.8FGVR Series

Page 1: ...D STATES CANADA This warranty does not cover installation or labor charges and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstance...

Page 2: ...ant parallel approach decrease spout height to 30 maximum above finished floor Provide clear floor space as required A171 8FGVR Page 2 of 15 Revised 07 18 18 7020 927 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATE...

Page 3: ...t louvers 4 Completely flush supply lines of all foreign debris before connecting to fixture Water cooler is designed to not cause problems with taste odor color or sediment Optional water filter Wf1 is available should any of these problems arise from the water supply 5 Do NOT solder tubes inserted into the coupler as damage to the o ring may result 7 Power supply must be identical in voltage cyc...

Page 4: ...ng points to level unit if necessary 5 Thoroughly flush the 3 8 O D supply line and then connect water cooler to water supply angle stop valve by others with supplied 3 8 O D copper tube 6 Make up 1 1 4 O D p trap by others waste connection START UP 1 Before connecting power supply and assembling bottom cover to water cooler but after thoroughly flushing the supply line and connecting it to the fi...

Page 5: ... 2169 000 000 TUBING LLDPE BLUE 1 4 OD 5 3 7012 311 000 WF1 FILTER 1500 GALLON 1 ITEM PART NUMBER DESCRIPTION QTY 1 7012 055 000 FOAM INSULATION PIPE 3 8 ID x 1 4 THICK 5 5 2 2169 000 000 TUBING LLDPE BLUE 1 4 OD 5 NON PRESSURIZED SINGLE UNIT PIPE INSTALLATION WITH FILTER WITHOUT GF BF OPTIONS 3 From the outlet of the cartridge assembly connect to the inlet of the evaporator assembly 2 From the ou...

Page 6: ...7 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of PRESSURIZED SINGLE UNIT PIPE INSTALLATION WITH GF BF OPTIONS ITEM PART NUMBER DESCRIPTION QTY 1 7012 055 000 FOAM INSULATION PIPE 3 8 ID x 1 4 THICK 5 5 2 2169 000 000 TUBING LLDPE BLUE 1 4 OD 5 17 Water Supply Tubing 13 Water Supply Tubing 1 2 To Bo...

Page 7: ...orator assembly connect to the inlet of the cartridge assembly I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S WATER COOLERS A171 8FGVR Page 7 of 15 Revised 07 18 18 7020 927 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 ...

Page 8: ...l Shim lower mounting points if necessary to level cooler 2 Compressor Does Not Run a Check the electrical receptacle for power and correct voltage The incoming voltage must be within 10 of the rated voltage on the serial nameplate b The cold thermostat is accessible by removing the bottom access cover If the cold thermostat capillary bulb loses its charge or becomes kinked it will fail in the ope...

Page 9: ...t See start up note 3 g The water cooler may also develop a freezing condition in which the water will become frozen inside the evaporator coil This indicates a refrigeration problem or thermostat failure in which case the water cooler needs to be checked by a qualified technician 7 Water Drip Or Will Not Shut Off a Remove Pushbutton Adjust flow regulator to the highest setting using a flat head s...

Page 10: ...rings 9 10 to access cartridge 5 Install item 11 using maintenance tool 5 Be careful not to over tighten 7 Reinstall strainer 4 and plug 3 using maintenance tool 5 4 Remove cartridge retaining nut 11 Remove and replace cartridge 2 When replacing cartridge be sure to align the inlet and outlet ports on the cartridge with the ports in the valve body 6 Install button assembly items 6 7 8 9 10 using m...

Page 11: ...TIONAL WF1 WATER FILTER ITEM PART NUMBER DESCRIPTION 1 7012 311 000 WF1 Filter 1500 Gal 2 1895 709 000 Elbow Push in 1 4 O D x 1 4 Stem 3 2169 000 000 1 4 O D LLDPE Tubing Blue 4 7012 055 000 Foam Pipe Insullation 5 7003 670 001 Filter Assembly FG FILTER MOUNTING DETAIL LINE TO DRINKING FOUNTAIN INLET INSTALLED FILTER DETAIL NOTES 1 CUT AND DEBURR WATER LINE TUBING AS REQUIRED 2 ENSURE TUBING END ...

Page 12: ...ove and replace the cartridge turning clockwise to secure 6 Turn water inlet 1 4 turn knob 1 4 turn counterclockwise to open and test for leaks and proper operation before closing access panel 3 With the water filter removed from the bracket assembly hold the cap firmly Turn the replaceable cartridge filter counterclockwise to remove 1 Remove access panel this allows access to the filter and the w...

Page 13: ...n fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N T...

Page 14: ...T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S WATER COOLERS A171 8FGVR Page 14 of 15 Revised 07 18 18 7020 927 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of Cartridge Retaining Nut Removal of P E Tubing from Push in Fittings Button Removal...

Page 15: ...R BRACKET 17 7003 681 299 ACCESS PLATE VR AUTO STOP 18 7000 006 000 FLAT DRAIN ADAPTER GASKET 19 7000 005 199 DRAIN ADAPTER 20 7000 019 001 WASTE TAILPIECE ASSEMBLY 21 7003 300 005 BACK PANEL ASSEMBLY 22 7003 604 002 ACCESS PANEL 23 2169 000 000 1 4 O D TUBING 24 7012 055 000 TUBE INSULATION 25 7003 194 199 VR MAINTENANCE TOOL 26 7003 198 199 VR PUSHBUTTON MOUNTING SLEEVE 27 0124 055 000 8x3 4 PHI...

Reviews: