background image

P E T  F O U N T A I N

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

INSTALLATION INSTRUCTIONS FOR M-PM54 PET FOUNTAIN

MAINTENANCE

All normal maintenance is done from above ground.

v

Always shut off water supply when doing any 

maintenance.

v

 

To remove pedestal mounted pushbutton

 assembly 

remove access panel. From inside the of the pedestal, 
remove inlet and outlet lines from push-in ports of the valve 
body. Using a spanner wrench remove pushbutton retaining 
ring.

v

 To replace regulator, 

use a spanner wrench to remove 

pushbutton and retaining ring from the flange collar. Use a 
spanner wrench to remove the retainer from the inside of the 
flange collar. Remove regulator, insert new regulator and 
align ports to new regulator with mating ports of valve body 
then replace retaining ring.

v

 

Re-assemble in reverse order. 

When replacing inlet 

and outlet line ensure to insert supply line to valve port 
labeled “IN”. Ensure plastic lines are not kinked when 
fountain is reassembled.

Valve Body w/

Flange Collar

Brass Nut

Regulator

Retainer

Fiber Ring

Rubber Gasket

Retaining

Ring

Pushbutton

1/4" Push-In

Elbows

The water flow can be adjusted using a slotted 
narrow blade screwdriver and turning clockwise to 
increase flow and counterclockwise to decrease flow.

INCREASE

FLOW

DECREASE

FLOW

Ø3/16"

HOLE

SLOTTED
SCREWDRIVER

FLOW ADJUSTMENT

Please visit

 www.murdockmfg.com

 

for most current specifications.

 

M-PM54

Page 2 of 2

Revised: 

04/26/17

7109-606-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of