P E T F O U N T A I N
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
INSTALLATION INSTRUCTIONS FOR M-PM54 PET FOUNTAIN
MAINTENANCE
All normal maintenance is done from above ground.
v
Always shut off water supply when doing any
maintenance.
v
To remove pedestal mounted pushbutton
assembly
remove access panel. From inside the of the pedestal,
remove inlet and outlet lines from push-in ports of the valve
body. Using a spanner wrench remove pushbutton retaining
ring.
v
To replace regulator,
use a spanner wrench to remove
pushbutton and retaining ring from the flange collar. Use a
spanner wrench to remove the retainer from the inside of the
flange collar. Remove regulator, insert new regulator and
align ports to new regulator with mating ports of valve body
then replace retaining ring.
v
Re-assemble in reverse order.
When replacing inlet
and outlet line ensure to insert supply line to valve port
labeled “IN”. Ensure plastic lines are not kinked when
fountain is reassembled.
Valve Body w/
Flange Collar
Brass Nut
Regulator
Retainer
Fiber Ring
Rubber Gasket
Retaining
Ring
Pushbutton
1/4" Push-In
Elbows
The water flow can be adjusted using a slotted
narrow blade screwdriver and turning clockwise to
increase flow and counterclockwise to decrease flow.
INCREASE
FLOW
DECREASE
FLOW
Ø3/16"
HOLE
SLOTTED
SCREWDRIVER
FLOW ADJUSTMENT