P E T  F O U N T A I N

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

INSTALLATION INSTRUCTIONS FOR M-PM74 PET FOUNTAIN

l

  An  in-line  PRV  installed  on  the  supply  line  is 
recommended  to  ensure  a  working  water  pressure 
of 40- 60 psi.

Important:  Read  all  instructions  and  refer  to  local 
codes prior to installation.

l

  Local  soil  conditions  may  require  more  gravel  for 
drainage.

l

  It  is  recommended  to  include  a  supply  stop 
appropriate located on the supply line.

Depending  on  code  and  design  requirements,  drain 
may be open, french or sanitary connection. For french 
drain  place  a  minimum  of  three  cubic  feet  of  gravel 
under drain opening. Local soil conditions may require 
more gravel drainage.

l

  Piping  and  valve  must  be  drained  prior  to  being 
subjected to freezing temperatures.

Refill trench and hole, compacting back fill as required. 
Leave  sufficient  depth  in  hole  to  accommodate 
concrete pour, 4” minimum recommended.

Prepare slab area surrounding fountain spreading and 
compacting  gravel  as  necessary.  Prepare  form 
approximately 6” diameter to protect supply and waste 
stub outs. Protect exposed valve assembly, tubing and 
tube  openings  to  prevent  damage  to  equipment  or  to 
prevent  tubes  from  becoming  filled  with  soil  or  debris. 
Then pour concrete, ensure concrete is flat and level.

Prepare trench for water supply lines and waste line (if 
required).  At  fountain  location  prepare  hole  to  trench 
depth  and  large  enough  for  a  person  to  work  in.  Lay 
supply  and  waste  into  trench  and  above  ground 
allowing extra line to be trimmed during hook up, refer 
to details for roughs.

l

 Supply line must be flushed of all foreign materials 
such as pipe dope, chips, etc.

l

 A water filter should be installed on the supply line if 
sediment or mineral content is a problem.

4" REC

MIN

2" PVC DWV DRAIN

PIPE RECOMMENDED,

BY OTHERS

12"

REF

4" REF

LEVEL

ACCESS PANEL

SUPPLY INLET

CONNECTION FOR

Ø1/4" PLAIN END,

BY OTHERS

EARTH

GRAVEL

POURED

CONCRETE

1/2"-13 UNC MTG

HARDWARE,

PROVIDED

FROST LINE

MINIMUM 3 CUBIC
FEET OF POROUS
GRAVEL FILL

NOTE: FRENCH DRAIN SHOWN.

CONSULT LOCAL CODE

REQUIREMENTS.

FOR FREEZE RESISTANT
OPTION REFER TO -FRU
MANUAL #9938-340-0M1

VALVE SPECIFICATIONS:

MINIMUM/MAXIMUM PRESSURE:

30/100 PSI

WASTE CONNECTION

FOR Ø1-1/4" OD CLOSE

ELBOW, BY OTHERS

TYP

Please visit

 www.murdockmfg.com

 

for most current specifications.

 

M-PM74

Page 1 of 3

Revised: 

08/31/18

7020-971-001