9. If necessary etc., cover the splice with additional material (PVC-Z-foil,
PU-Z-foil) (Fig. 3).
10. Depending on the belt type, place the prescribed cover material (sili-
cone embossing mat, separating paper, textured fabric fine etc.) (Fig.
4).
11. Cover the splice with the top pressure equalizing metal sheet.
12. Place the top heating plate.
13. Place the top pressure beam with pressure hose.
5.3
Closing the heating press
1. Slightly tighten nut by hand.
2. Only then fill the pressure hose with air.
(maximum 7 bar)
Note:
The feeding of compressed air is not automatically
controlled and must be done in form of a stationary
compressed air network or a compressor system.
A pressure display does not exist!
Warning
Risk of injury! The permitted maximum air pressure for generating the pressing force is 7
bars. If you exceed this maximum figure, the device can burst!
Nut
Centering bore
Centering pin
Eye bolt