Service Manual
PV18-2K/3K HM
- 10 -
Q17
Q18
3.3 To Check Full-Bridge Invert Circuit
3.3.1 Power Parts
Q16,Q17,Q18,Q19:150-30088-00 (IGBT IR/IRGP4063D-EPBF 48A 600V TO-247)
Positioning
Attribute
Reference Value
Failure Status
Q16,Q17,Q18,Q19
Diode
EC: 0.4V
CE: OL
Short Circuit
or Broken
3.3.2 Divers
INV IGBT: Q16,Q17,Q18,Q19
Q16
Q17
Q18
Q19
G
C
E