16
MUSTANG SURVIVAL
/ OWNER'S MANUAL –
DLX 38 INFLATABLE PFD
10.
Raise, and hold, the lever into the inflator housing
. The pull-cord
should be situated in the groove (Fig. 17). Install a new cylinder/
bayonet assembly by engaging bayonet tabs in housing, pushing
in then turning clockwise 1/8 turn to a full stop (Fig. 17).
WARNING: PFD WILL ONLY INFLATE IF CYLINDER IS TURNED TO A FULL STOP.
11. Examine the service indicator (Fig. 15) and ensure it is
GREEN
. If
the service indicator is red, the mechanism has been fired or is
incorrectly fitted and the inflator requires service. (see "Re-arming
Your Automatic PFD (MD2953)" on p. 14).
NOTE: THE SERVICE INDICATOR MUST BE GREEN BEFORE PROCEEDING.
12. Refold the Inflatable PFD in accordance with the Repacking
section (See Repacking, p. 17).
Your inflatable PFD (MD2953) is now ready for manual use with
automatic backup.
Service
Indicator
Groove
Pull-cord
Tab
Piercing
Pin
Cylinder
MD2953 Automatic Inflator
1/8 Turn
Fig. 17