Automatic Aligning System
ValueCut USER MANUAL
56
VC2E-A-00
5.2 AAS Contour Cutting System
The AAS Contour Cutting system has one calibration procedures to ensure maximum accuracy of AAS
operation. To operate the AAS you need to learn about the method of media feeding firstly. (Refer to 4.1
Media Loading)
5.2.1 Media Calibration
Media Calibration is to ensure the sensor being able to recognize the registration marks.
The factory default works on a wide range of materials. However, certain types of materials may
not work properly. Performing a media calibration may become necessary while working with
such materials to change the sensitivity of AAS for greater reliability. Media calibration adjusts
the media feeding according to media type for better accuracy during cutting.
When to use
We suggest white media for best cutting result. It is not necessary to perform media
calibration every time unless the registration marks on the printed media become
undetectable in AAS sensing process.
5.2.2 Notice for Registration Marks
The first registration mark is designed to be different in order to identify the origin for AAS
auto-detection. The following precaution must be aware for registration marks to be read
automatically.
Type of media
Registration mark pattern
Reading range required for detection the registration marks
Position for registration marks and medium
The registration marks have to be:
Created by cutting software for ValueCut
In black color (printing quality of registration marks is essential; incorrect, misaligned colors,
blurry or smeared printout might leading to inaccurate cutting result)
Length: The length of marks
Range: 10 mm ~ 50 mm
Optimized Setting: 25 mm
Thickness: The line thickness of marks
Range: 1 mm ~ 2 mm
Optimized Setting: 1 mm
Summary of Contents for ValueCut II Series
Page 60: ...Automatic Aligning System ValueCut USER MANUAL 60 VC2E A 00 Figure 5 1 Figure 5 2...
Page 111: ......
Page 112: ......