3.1 INSTALLATION ENVIRONMENT
Be sure to read and understand the safety warnings before handling the printer.
3.1.1 Environmental conditions for installation
Floor strength of the installation place
More than 2940 Pa (300 kg/m²)
Power Specifications
Power Supply
AC90V 132V/198V 264V
Frequency Range
50/60Hz ± 1Hz
Power Capacity
Main: 8.5 A / 4.5A
Heater: 8.5 A / 4.5A
Environmental conditions
Operative Condition
Temperature: 20°C to 32°C
Humidity: 40% to 60%, No condensation
Guaranteed range of
printing accuracy
Temperature: 22°C to 30°C
Humidity: 40% to 60%,
Change rate
Temperature: within 2°C per hour
Humidity: within 5% per hour
Archiving environment
Temperature: - 20°C to 60°C
Humidity: 20% to 80%,
No condensation ( Ink unfilled)
Notes
Concerning temperature and humidity, avoid:
±
Places where temperature or humidity may rapidly change, even though within the required
conditions.
±
Places that receive direct sunlight, increased illumination or direct air, for example from an air
conditioner.
To keep the temperature and humidity constant, install this product in a location where the air condition
is adjustable.
3.1.2 Installation space
Install the printer on a levelled floor which has enough strength to support the weight of the entire machine.
Notes
For the weight of the printer and the stand, please refer to the Operation Manual.
A
650 mm
E
1550 mm
B
1000 mm
F
3800 mm
C
1000 mm
G
2700 mm
D
1000 mm
Total height with cassettes mounted = 1600 mm