+44 (0)23 8052 2345
15
MV Heating UK Ltd
Part 6: The Combustion Chamber
Tools:
•
1 x 3mm Hex Key
•
1 x Pliers
Removing the Combustion Chamber:
1)
Remove the cases (
Part 1
), the E.C.U. (
Part 3
), the air motor (
Part 4
), and
the burner assembly (
Part 5
).
2)
Undo the 4 x 4mm hex bolts from the top of the combustion chamber.
3)
Using a pair of pliers, remove the combustion chamber (
2:7
). This can be
stiff as the rubber O-ring can become bonded between the chamber
and heat exchanger.
4)
Remove the rubber O-ring (
2:8
) from its position inside the combustion
chamber and discard.
Refitting the Combustion Chamber:
1)
Place a new rubber O-ring (
2:8
) into the recess of the combustion
chamber.
2)
Insert the combustion tube (
2:7
) back into the heat exchanger (
2:9
).
3)
Replace and tighten the 4 x hex bolts into the top of the combustion
chamber to 4 ± 0.4 Nm to secure it in place.
4)
Replace the burner assembly (
Part 5
), the air motor (
Part 4
), the E.C.U.
(
Part 3
), and the cases (
Part 1
).