background image

TECHNICAL SPECIFICATIONS 

INSTALLATION 

TRANSPORTATION 

1. To  prevent  the  oil  contained  in  the  compressor  from  flowing  into  the  cooling  circuit,  it  is

necessary  to  always  carry,  store  and  handle  the  unit  in  a  vertical  position  and  follow  the
instructions found on the packaging.

2. If the unit was placed in a non-vertical position during the transportation, keep the unit in a

vertical position for approximately 24 hours before using the unit and turning it on, to allow
the oil to flow back into the compressor.

UNPACKING 

1. Remove the wooden baseboard and plastic covering.
2. Make sure that the unit has not been damaged.
3. Remove plastic film from all the stainless-steel panels, if applicable.

IMPORTANT

:

The packaging should be kept away from children as it is potentially dangerous. 

Dispose of the packaging according to the regulation from the local authorities. 

MODEL 

KGC-

50

 

KGC-62 

KGC-74 

Number of Pans (1/3 GN or Italy Pan) 

12 

16 

20 

Numbers of rear sliding doors (Arclic) 

HP 

1 1/4 

1 1/2 

Electrical 

110V/60HZ/1P 

Amps 

10.5 

12.3 

13.5 

Temperature Range (

0

-8 

Refrigerant 

R404A/R448 

Dimensions

 

49.2"*44.8"*48.3"  62.2"*44.8"*48.3"  75.2"*44.8"*48.3" 

Shipping Weight (lbs.) 

723 

850 

961 

Summary of Contents for Kool-It KGC Series

Page 1: ...Free 888 275 4538 Fax 514 342 3854 Toll Free 877 453 8832 sales mvpgroupcorp com mvpgroupcorp com Gelato Display Freezer KGC Series User Manual 12000 Biscayne Blvd Ste 108 Miami FL 33181 Telelephone 786 600 4687 TollFree 844 218 8477 Fax 786 661 4100 service mvpgroupcorp com ...

Page 2: ...1 TABLE OF CONTENTS Section Page Technical Specifications 2 Installation 2 3 Operation 3 6 Maintenance 6 8 Parts Breakdown 8 12 Electrical Diagram 12 ...

Page 3: ...low back into the compressor UNPACKING 1 Remove the wooden baseboard and plastic covering 2 Make sure that the unit has not been damaged 3 Remove plastic film from all the stainless steel panels if applicable IMPORTANT The packaging should be kept away from children as it is potentially dangerous Dispose of the packaging according to the regulation from the local authorities MODEL KGC 50 KGC 62 KG...

Page 4: ...ble should beenough for the maximum energy required by the unit 4 If necessary use multiple outlets which are all properly grounded in compliance with current safety standards 5 If in doubt please consult qualified technicians THE REFRIGERATED SHOWCASE MUST BE CONNECTEDTO AN ELECTRICAL SOCKETWITH A GROUND OPERATION Before using the unit should be completely cleaned as it comes into contact with fo...

Page 5: ...4 CAUTION You are suggested not to reset the temperature controller frequently Temperature Controller Operation Front Panel Commands Main Functions 1 How to see the setpoint ...

Page 6: ... temperature If fitted and enabled the buzzer and the alarm relay are also activated All the alarms have automatic reset that is they stop when the causes are no longer present except for alarm CHt which has manual reset instrument on off using the UP button or by disconnecting the power supply Pressing the SET button mutes the buzzer while the code displayed and the alarm relay ...

Page 7: ... interiors Rinse carefully with water to remove any soap residues 4 To maintain a high standard of working performance leave the unit turned on during the night and day to avoid deposits CAUTION Do not use any damaging solvents petrol alcohol etc for cleaning the unit The unit mayget damaged Do not use and sharp objects for cleaning The unit may be cleaned with a damp towel but should never direct...

Page 8: ...Turning to the working position Poor contract of thermostat Insert the plug tightly Loose plug pins in the starter Insert the plug tightly Broken compressor Replace Broken starter or capacitor Repair or replace Compressor runs but the temperature in the showcase is high Circulating temperature is too high Adjust the thermostat properly Ask for authorized service department to check and too much du...

Page 9: ... fan of the evaporator does not work The fan motor is damaged Replace WARNING If the machine has any problems or has been damaged do not try to repair or replace it by yourself Please contact KOOL IT technical service at 1 888 275 4538 PARTS BREAKDOWN ...

Page 10: ... stopper THCD 3 100 002 19 0 6mm 304 mirror stainless steel 17 Evaporator 2 THCD 3 300 004 03 copper pipe 18 Bottom cushion for front glass THCD 2 400 003 12 Transparent food grade silicone 19 Front panel for inner cabinet THCD 3 100 001 06 0 6mm 304 mirror stainless steel 20 Front glass THCD 3 300 003 01 glass 21 U shape PVC cover 2 THCD 3 400 003 11 Black PVC 22 Front cabinet panel THCD 3 100 00...

Page 11: ...d for compressor kit THCD 2 100 004 02 2 0mm cold roll steel 56 Adjustable legs THCD 2 200 004 01 57 Fan motor safety net wire cover NET WIRE Φ254 58 Fan blade Φ254 34 WEIGUANG 59 Condenser cover THCD 3 100 004 01 1 2mm galvanized plate 60 Condenser THCD 3 300 004 01 copper 61 Control panel THCD 2 100 003 09 0 6mm 304 mirror stainless steel 62 Under frame structure THCD 2 200 004 03 25 25 2 square...

Page 12: ... galvanized plate 91 Handle of the back sliding door 1 3 M4 92 U shape PVC 1 THCD 3 400 003 10 PVC Black 93 Back air wall for inside cabinet THCD 3 100 001 09 0 6mm 304 mirror stainless steel 94 Air outlet grille 2 THCD 3 100 002 02 1 0mm 304 mirror stainless steel 95 Connection board for air outlet grille THCD 3 100 002 04 0 6mm 304 mirror stainless steel 96 Rear sliding arclic door 1 THCD 3 200 ...

Page 13: ... 5mm galvanized plate 117 Left side glass THCD 2 300 003 03 118 Connection board for pan supporting arms 3 THCD 2 100 002 07 1 0mm 304 mirror stainless steel 119 Foamed panel 2 THCD 3 200 002 02 PVC panel 120 Connection board for pan supporting arms 2 THCD 3 100 002 06 1 0mm 304 mirror stainless steel 121 Left panel for inside cabinet THCD 2 100 001 10 1 0mm 304 mirror stainless steel 122 Connecti...

Page 14: ...13 ELECTRICAL DIAGRAM ...

Reviews: