Applicable to: B22 and B25 (a ll versions)
Revision 1.3 – 02/24/ 2015
Manual B – Operations
-
26
Graph POWER/MAP with constant RPM: each graph indicates the power output in reference
to the different values of RPM in function of MAP. The bold indicates the maximum
continuous power in function of the MAP.
5% difference from the graph is permitted.