14 Trouble shooting
Problem
Reason
Solution
The turntable rotate just in one direction
or can’t rotate.
Reverse switch broken.
Replace the reverse switch.
Belt broken.
Replace the belt.
Motor’s malfunction.
Check the motor cable or terminal block
wire.
Replace the motor if it is broken.
Demount or fix the wheel, the turntable
can’t lock.
The jaws delay to open/close.
The turntable locks the rim incorrectly.
Leakage of air network.
Check all the parts on the air network.
The clamping cylinder can’t work.
Replace the cylinder piston.
Worn jaws.
Replace the jaws.
Broken washers of the chuck cylinder.
Replace it.
The mounting/demounting head always
touch the rim during operation.
The locking plate incorrectly adjust or
unqualified.
Replace or adjust it.
Screws on the chuck loose. The
hexagonal vertical arm can’t be locked
by locking plate.
Tighten the screws, replace the locking
plate.
The bead breaker pedal and jaw open
and close pedal can’t turn back to the
original position.
Pedal spring broken.
Replace it.
The bead breaker shovel operates
difficultly.
Jammed silencer.
Clean it or replace it.
The washer on the bead breaker
cylinder is broken.
Replace it.