Page 1: ...vertical the input terminals at the bottom and output on the top Mounting orientations other than that such as upside down horizontal or table top mounting is not allowed 3 Use copper wire only and recommended wires are shown as below AWG 18 16 14 12 10 Rated Current of Equipment Amp 7 10 15 25 32 Cross section of Lead mm2 0 8 1 3 2 1 2 5 4 Note Current each wire carries should be de rated to 80 o...

Page 2: ...earance must be kept when the adjacent device is a heat source 3 The recommended torque setting for terminals is shown as below Model I P O P ICL 16L 5 7 kgf cm 5 Lb in 5 7 kgf cm 5 Lb in ICL 28L 5 7 kgf cm 5 Lb in 5 7 kgf cm 5 Lb in 4 Use copper wire only and recommended wires are shown as below AWG 18 16 14 12 10 Rated Current of Equipment Amp 7 10 15 25 32 Cross section of Lead mm2 0 8 1 3 2 1 ...

Page 3: ...ted from foreign objects or dripping liquids 5 Only install the unit in a pollution degree 2 environment Note 1 6 Please do not install the unit in places with high moisture or near the water 7 The maximum operating temperature is 70 C for the ICL 16R 16L and 60 C for the ICL 28R 28L please do not install the unit in places with high ambient temperature or near fire source 8 Disconnect system from...

Page 4: ...present the decisive factor because the inrush current limiters can handle capacitive loads as high as 2500uF 6000uF The input capacity of the power supplies is largely determined by primary side storage capacitors With MEANWELL these capacitors are marked with the position code C5 and their capacitance can be found in the test report on the MEANWELL s website Regarding the q ty of PSU can be conn...

Page 5: ...Installation Manual For other model you can use the same method to calculate it ...

Page 6: ...roducts Appendix B adopting table look up to verify the Environment Friendly Use Period Names and Contents of Hazardous Substances Lists Part Name Hazardous Substances Lead Pb Mercury Hg Cadmium Cd Hexavalent chromium Cr6 Polybrominated biphenyls PBB Polybrominated diphenyl ethers PBDE PCB and its components X O X O O O Metal structure parts X O O O O O Plastic structure parts O O O O O O Accessor...

Page 7: ... to China s Standardization Administration Releases VOC Standards Standard No Name of the Standard GB 30981 2020 Limit of harmful substances of industrial protective coatings GB 33372 2020 Limits for volatile organic compounds content in adhesive GB 38507 2020 Limits for volatile organic compounds VOCs In printing ink GB 38508 2020 Limits for volatile organic compounds content in cleaning agents ...

Page 8: ...reby confirms that MEAN WELL product series comply with Use and Risk Management for Five PBT Chemicals under TSCA section 6 h CAS No Substance Name 1163 19 5 Decabromodiphenyl ether DecaBDE 68937 41 7 Phenol isopropylated phosphate 3 1 PIP 3 1 732 26 3 2 4 6 Tris tert butyl phenol 2 4 6 TTBP 133 49 3 Pentachlorothiophenol PCTP 87 68 3 Hexachlorobutadiene HCBD ...

Reviews: