* The tray of the scale can also be used as a weighing cup or bowl. Simply turn it upside down and place it on 
the weighing platform.

* Avoid lengthy exposure to extreme heat or cold, your scale works best when operated at normal room 
temperature. 

Always allow the unit to acclimate to a normal room temperature for at least one hour 

before use.

* Allow sufficient warm up time. Turn the scale On and wait several seconds to give the internal components a 
chance to stabilize before weighing. 

* The cleaner the environment the better. Dust, dirt, moisture, vibration, air currents and proximity to other 
electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale. Only use on 
a stable, vibration free surface

* Handle with care. Gently apply all items to be weighed onto tray top. Although this scale is designed to be 
quite durable, try to avoid rough treatment as this may permanently damage the internal sensor and void your 
warranty.

* Avoid shaking, dropping or otherwise shocking the scale. This is a precision instrument and MUST BE 
HANDLED WITH EXTREME CARE.

*

IMPORTANT ADVICE: Place the item to be weighed on the platform, after the stable weight is 

displayed remove the item immediately. This will prolong the longevity and accuracy of this weighing 
instrument.

.** These electronic scale are precision instruments. Do not operate near an in-use cell phone, cordless phone, 
radio, computer or other electronic device. These devices emit RF and can cause unstable scale readings. If 
your scale ever performs poorly, try moving the scale to a different room or location. This is a very precise 
scale - the display may seem to wander or jump when weighing. This is due to air currents or vibrations. Stable 
weighing is achieved when the display remains fixed for 3 seconds.

FEATURE_______________________________________________

* Power Up Segment Test & Stabilization

When first turning the unit on, the segments of the display will appear as shown below. This display will remain 
for approximately 

5 seconds

 and then reset to 0. 

 OPERATION____________________________________________________

When all segments flash on the display, this indicates the batteries are low 

Battery Replacement:

DO NOT USE EXCESSIVE FORCE & DO NOT PRESS ON THE TRAY!!!

 

1) Four "AAA" size alkaline batteries are required.

2) To install batteries:

a) Release both battery covers by holding the tab and pulling out-wards.

b) Place batteries into battery compartment aligned correctly.

c) Replace battery cover.

3) The scale is now ready for battery operation.

http://myweigh.com/support_manual_durascale.html (2 of 6)7/25/2006 8:20:58 PM

Summary of Contents for durascale 50

Page 1: ...th all of our scales but batteries can run low in storage If your scale simply won t turn on while on Battery power this is often caused by loose battery connections Battery prongs terminals are made of metal They must be making good contact with your batteries in order for the scale to power on You can use a paperclip to slightly bend the battery prongs to make them have a better connection Also ...

Page 2: ...oid rough treatment as this may permanently damage the internal sensor and void your warranty Avoid shaking dropping or otherwise shocking the scale This is a precision instrument and MUST BE HANDLED WITH EXTREME CARE IMPORTANT ADVICE Place the item to be weighed on the platform after the stable weight is displayed remove the item immediately This will prolong the longevity and accuracy of this we...

Page 3: ...nstructions below are for each model so if you re not sure try both sets of instructions to see which one will work for your scale Older D 100 Easy Calibration Start with the scale powered off and nothing on the weighing platform 1 press and hold both the ON OFF and TARE keys until CAL 0 appears on the display 2 Press TARE the 0 in CAL 0 will flash 3 When CAL 50 shows on the display Place a 50g ca...

Page 4: ...ge and flash 3 When you have set the desired value for the auto off time press TARE to save the setting and then press ON OFF to exit the auto off time programming mode DISPLAY DATA HOLD LOCK FUNCTION SET This advanced scale is equipped with a display lock setting to be used when you wish to keep a displayed value on the display This works well when counting or reloading The hold system works by n...

Page 5: ...eight value of a container weight is permanently removed for the remainder of the procedure Just turn the scale ON place the tray or container on weighing platform and press the ZERO key The scale will show 0 00 or 0 0 on the display and you can add items to the container tray NOTE When all weight are removed from the weighing tray the tared value of a container will be displayed as a negative num...

Page 6: ...y be solved by following method 1 Prepare a small screwdriver a fine point tweezer 2 Lightly move away the QC paster on the back of the scale using the tweezer now you will see an adjustable resistor from the hole on the scale back shell 3 When the scale is off press and hold down ON OFF key then press down UNIT key until Hld oN or Hld oF is displayed 4 Press Pcs key the scale will display inner c...