background image

Durascale precision digital pocket scale manual

(Advanced users only) CALIBRATION

______________________________

IMPORTANT: This scale was professionally factory calibrated before shipment and does NOT need to be 
recalibrated by the end user. However, if you wish to recalibrate your scale we provide these instructions for 
calibration:

 

Repeat calibration if the scale performs inaccurately. Incorrect calibration can occur if you do not 

follow the steps exactly. You will need a 50gram weight or set of weights to calibrate this scale (included in the 
box).

DURASCALE 50 Easy Calibration:

There are two models of the Durascale.  The older Durascales need to begin calibration with the 
scale turned OFF.  The newer Durascales need to begin calibration with the scale turned ON
 

*Start with the scale 

powered off or on as per above 

and nothing on the weighing platform. 

1) press and hold both the ‘ON/OFF’ and ‘TARE’ keys until ‘CAL-0’ shows on the display
2) Press ‘TARE’, the ‘0’ in ‘CAL-0’ will flash;
3) When ‘CAL-F’ shows on the display, Place the 50gram calibration weight on the weighing platform 
4) Press ‘TARE’, the ‘F’ in ‘CAL-F’ will flash ;
5) When ‘CAL-0’ appears on the display, remove the 50gram weight from the platform
6) Press ‘TARE’ , the ‘0’ in ‘CAL-0’ will flash
When the calibration is finished, the scale will automatically turn off/reset

NOTE:

 if after calibration your scale does not read accurately, this indicates

calibration error and the calibration process should be repeated more slowly. 

Please calibrate on a very stable flat surface

DURASCALE 100 Easy Calibration:

There are two models of the Durascale 100.  The instructions below are for each model so if you're not 
sure - try both sets of instructions to see which one will work for your scale.

(Older D-100) Easy Calibration: 
*Start with the scale powered off and nothing on the weighing platform. 
1) press and hold both the ‘ON/OFF’ and ‘TARE’ keys until ‘CAL-0’ appears on the display 
2) Press ‘TARE’, the ‘0’ in ‘CAL-0’ will flash; 
3) When ‘CAL-50’ shows on the display, Place a 50g calibration 
weight on the platform and press 'TARE', the'50' in 'CAL-50' will flash; 
4) When 'CAL-F' shows on the display, Place another 50g calibration 
on the platform and press 'TARE' , the 'F' in 'CAL-F' will flash ; 
5) When 'CAL-0' appears , remove all weights from the platform and 
then press ‘TARE’ , the ‘0’ in ‘CAL-0’ will flash; 
When the calibration is finished, the scale will automatically turn 
off/reset 
NOTE: if after calibration your scale does not read accurately, this indicates 
calibration error and the calibration process should be repeated more slowly. 
Please calibrate on a very stable flat surface

(Newer D-100) Easy Calibration: 
*Start with the scale powered ON and nothing on the weighing platform.  
1) press and hold ‘TARE’ until ‘CAL-0’ shows on the display 
2) Press ‘TARE’, the ‘0’ in ‘CAL-0’ will flash; 
3) When ‘CAL-F’ shows on the display, Place the 100gram calibration weight on the weighing platform  
4) Press ‘TARE’, the ‘F’ in ‘CAL-F’ will flash ; 
5) When ‘CAL-0’ appears on the display, remove the 100gram weight from the platform 
6) Press ‘TARE’ , the ‘0’ in ‘CAL-0’ will flash 
When the calibration is finished, the scale will automatically turn off/reset NOTE: if after calibration 
your scale does not read accurately, this indicates 
calibration error and the calibration process should be repeated more slowly.  
Please calibrate on a very stable flat surface

http://myweigh.com/support_manual_durascale.html (3 of 6)7/25/2006 8:20:58 PM

Summary of Contents for durascale 50

Page 1: ...th all of our scales but batteries can run low in storage If your scale simply won t turn on while on Battery power this is often caused by loose battery connections Battery prongs terminals are made of metal They must be making good contact with your batteries in order for the scale to power on You can use a paperclip to slightly bend the battery prongs to make them have a better connection Also ...

Page 2: ...oid rough treatment as this may permanently damage the internal sensor and void your warranty Avoid shaking dropping or otherwise shocking the scale This is a precision instrument and MUST BE HANDLED WITH EXTREME CARE IMPORTANT ADVICE Place the item to be weighed on the platform after the stable weight is displayed remove the item immediately This will prolong the longevity and accuracy of this we...

Page 3: ...nstructions below are for each model so if you re not sure try both sets of instructions to see which one will work for your scale Older D 100 Easy Calibration Start with the scale powered off and nothing on the weighing platform 1 press and hold both the ON OFF and TARE keys until CAL 0 appears on the display 2 Press TARE the 0 in CAL 0 will flash 3 When CAL 50 shows on the display Place a 50g ca...

Page 4: ...ge and flash 3 When you have set the desired value for the auto off time press TARE to save the setting and then press ON OFF to exit the auto off time programming mode DISPLAY DATA HOLD LOCK FUNCTION SET This advanced scale is equipped with a display lock setting to be used when you wish to keep a displayed value on the display This works well when counting or reloading The hold system works by n...

Page 5: ...eight value of a container weight is permanently removed for the remainder of the procedure Just turn the scale ON place the tray or container on weighing platform and press the ZERO key The scale will show 0 00 or 0 0 on the display and you can add items to the container tray NOTE When all weight are removed from the weighing tray the tared value of a container will be displayed as a negative num...

Page 6: ...y be solved by following method 1 Prepare a small screwdriver a fine point tweezer 2 Lightly move away the QC paster on the back of the scale using the tweezer now you will see an adjustable resistor from the hole on the scale back shell 3 When the scale is off press and hold down ON OFF key then press down UNIT key until Hld oN or Hld oF is displayed 4 Press Pcs key the scale will display inner c...