background image

Durascale precision digital pocket scale manual

(ounces) gn (grains), ozt (troy ounces), dwt (pennyweight), mg (miligrams) or ct (carats).

ON/OFF

Press this key to turn unit on. Once the unit is on, press the same key to turn the scale off

* PCS - PARTS COUNTING MODE

1)

 In normal weighing mode, Press ‘PCS’ to prepare to enter the parts counting mode. ‘Cnt.--’ will be displayed 

and ‘--’ will flash; (Cnt means Count mode).

2)

 When the scale has stabilized, ‘Cnt.

xx

’ will be displayed (

xx

 means a value of rd, 10, 20, 30, 40, or 50 - "rd" 

means the unit weight of the last item you weighed)

3)

 Press the ‘UNIT’ key, ‘

xx’

 will change to rd, 10, 20, 30, 40, or 50 (select the quantity value you wish to use 

for counting) 

4)

 Place the number of items on the tray that you selected in step 3 (for example, 20 pieces of an item)

5)

 Press ‘TARE ’ to confirm the above setting and begin counting 

OR

 When ‘Cnt.rd’ is selected , Press ‘TARE’ 

to recall the last unit weight to count parts;

6)

 When ‘xx pc’ is displayed (small pc in the upper part of the display, for example, ‘20 pc') is displayed, the 

scale is in parts counting mode, You can place any quantity of an item on the tray and it will tell you the total 
number of items. You can also perform the following operations:

<1>Press ‘PCS’ to exit parts counting state and go into normal weighing state;

<2> Press ‘TARE’ , to re-zero the scale

<3>Press ‘ON/OFF’, to turn off the scale

ZERO (TARE)

Press Zero to reset the scale to zero. This can be used for eliminating from a sample (or a Tray/Container) the 
weight value of a container weight is permanently removed for the remainder of the procedure. Just turn the 
scale ON, place the tray or container on weighing platform, and press the ZERO key. The scale will show 0.00 
(or 0.0) on the display and you can add items to the container/tray.

NOTE: When all weight are removed from the weighing tray, the tared value of a container will be displayed as 
a negative number. Cycle the power on the scale or press the TARE key to reset the scale to zero.

** These electronic scale are precision instruments. Avoid disturbing environmental conditions such as 
currents, vibrations, strong electrical and magnetic fields as well as a rapid change of the ambient temperature.

A.ch.Er User Repair:

If your display is stuck showing A.ch.Er,   it means that the signal coming from the load cell to the processor is 
out of the range of normal.  The most often cause of this is that the load cell has been pushed down due to 
accidental overload (often when people are changing the batteries they accidentally push down on the tray).  
Most of the time this can be fixed by simply pulling or prying up on the tray (to bend the load cell slightly up so 
that it will be within spec).      We build a lot of overload protection into our design,  but especially with a precise 
0.01gram scale,  it's still possible to accidentally overload the scale.

Here is a typical email from a Durascale owner that fixed the problem using the above instructions: "

OK I pulled 

up on each side of the platform very gently. It flexed just a fraction of an inch, but it didn't seem to be stuck down. I turned 

http://myweigh.com/support_manual_durascale.html (5 of 6)7/25/2006 8:20:58 PM

Summary of Contents for durascale 50

Page 1: ...th all of our scales but batteries can run low in storage If your scale simply won t turn on while on Battery power this is often caused by loose battery connections Battery prongs terminals are made of metal They must be making good contact with your batteries in order for the scale to power on You can use a paperclip to slightly bend the battery prongs to make them have a better connection Also ...

Page 2: ...oid rough treatment as this may permanently damage the internal sensor and void your warranty Avoid shaking dropping or otherwise shocking the scale This is a precision instrument and MUST BE HANDLED WITH EXTREME CARE IMPORTANT ADVICE Place the item to be weighed on the platform after the stable weight is displayed remove the item immediately This will prolong the longevity and accuracy of this we...

Page 3: ...nstructions below are for each model so if you re not sure try both sets of instructions to see which one will work for your scale Older D 100 Easy Calibration Start with the scale powered off and nothing on the weighing platform 1 press and hold both the ON OFF and TARE keys until CAL 0 appears on the display 2 Press TARE the 0 in CAL 0 will flash 3 When CAL 50 shows on the display Place a 50g ca...

Page 4: ...ge and flash 3 When you have set the desired value for the auto off time press TARE to save the setting and then press ON OFF to exit the auto off time programming mode DISPLAY DATA HOLD LOCK FUNCTION SET This advanced scale is equipped with a display lock setting to be used when you wish to keep a displayed value on the display This works well when counting or reloading The hold system works by n...

Page 5: ...eight value of a container weight is permanently removed for the remainder of the procedure Just turn the scale ON place the tray or container on weighing platform and press the ZERO key The scale will show 0 00 or 0 0 on the display and you can add items to the container tray NOTE When all weight are removed from the weighing tray the tared value of a container will be displayed as a negative num...

Page 6: ...y be solved by following method 1 Prepare a small screwdriver a fine point tweezer 2 Lightly move away the QC paster on the back of the scale using the tweezer now you will see an adjustable resistor from the hole on the scale back shell 3 When the scale is off press and hold down ON OFF key then press down UNIT key until Hld oN or Hld oF is displayed 4 Press Pcs key the scale will display inner c...

Reviews: