Durascale precision digital pocket scale manual
(ounces) gn (grains), ozt (troy ounces), dwt (pennyweight), mg (miligrams) or ct (carats).
*
ON/OFF
Press this key to turn unit on. Once the unit is on, press the same key to turn the scale off
* PCS - PARTS COUNTING MODE
1)
In normal weighing mode, Press ‘PCS’ to prepare to enter the parts counting mode. ‘Cnt.--’ will be displayed
and ‘--’ will flash; (Cnt means Count mode).
2)
When the scale has stabilized, ‘Cnt.
xx
’ will be displayed (
xx
means a value of rd, 10, 20, 30, 40, or 50 - "rd"
means the unit weight of the last item you weighed)
3)
Press the ‘UNIT’ key, ‘
xx’
will change to rd, 10, 20, 30, 40, or 50 (select the quantity value you wish to use
for counting)
4)
Place the number of items on the tray that you selected in step 3 (for example, 20 pieces of an item)
5)
Press ‘TARE ’ to confirm the above setting and begin counting
OR
When ‘Cnt.rd’ is selected , Press ‘TARE’
to recall the last unit weight to count parts;
6)
When ‘xx pc’ is displayed (small pc in the upper part of the display, for example, ‘20 pc') is displayed, the
scale is in parts counting mode, You can place any quantity of an item on the tray and it will tell you the total
number of items. You can also perform the following operations:
<1>Press ‘PCS’ to exit parts counting state and go into normal weighing state;
<2> Press ‘TARE’ , to re-zero the scale
<3>Press ‘ON/OFF’, to turn off the scale
*
ZERO (TARE)
Press Zero to reset the scale to zero. This can be used for eliminating from a sample (or a Tray/Container) the
weight value of a container weight is permanently removed for the remainder of the procedure. Just turn the
scale ON, place the tray or container on weighing platform, and press the ZERO key. The scale will show 0.00
(or 0.0) on the display and you can add items to the container/tray.
NOTE: When all weight are removed from the weighing tray, the tared value of a container will be displayed as
a negative number. Cycle the power on the scale or press the TARE key to reset the scale to zero.
** These electronic scale are precision instruments. Avoid disturbing environmental conditions such as
currents, vibrations, strong electrical and magnetic fields as well as a rapid change of the ambient temperature.
A.ch.Er User Repair:
If your display is stuck showing A.ch.Er, it means that the signal coming from the load cell to the processor is
out of the range of normal. The most often cause of this is that the load cell has been pushed down due to
accidental overload (often when people are changing the batteries they accidentally push down on the tray).
Most of the time this can be fixed by simply pulling or prying up on the tray (to bend the load cell slightly up so
that it will be within spec). We build a lot of overload protection into our design, but especially with a precise
0.01gram scale, it's still possible to accidentally overload the scale.
Here is a typical email from a Durascale owner that fixed the problem using the above instructions: "
OK I pulled
up on each side of the platform very gently. It flexed just a fraction of an inch, but it didn't seem to be stuck down. I turned
http://myweigh.com/support_manual_durascale.html (5 of 6)7/25/2006 8:20:58 PM