background image

SAFETY PRECAUTIONS 

 

All safety messages are identified by the following the words "

WARNING

" and 

"CAUTION". These words mean the following: 

 

WARNING

 

Important information to alert you to a 
situation that might cause serious injury and 
damage to your property if instructions are 
not followed. 

CAUTION 

Important information that tells how to prevent 
damage to equipment. 

 

When using the scale/balance, the following safety precautions should always be 
followed. 
 

△  

WARNING 

Use only the AC adaptor with the scale/balance. Other adaptor may cause 

damage. (AC adaptor is optional) 

 

△  

CAUTION 

 

Avoid installing the scale/balance in direct sunlight, this may cause discoloration or 
malfunctions. 

 

Do not mix the type of batteries. Replace all other batteries at the same time. 

 

If the scale/balance is not to be used for a long period of time, remove all batteries 

from the battery compartment to avoid leakage which may cause damage to the 

instrument. 

 

Avoid overloading that could cause damage to the scale/balance. 

 

Do not drop water in the scale/balance that is not water-resistant. It causes damage, 

if inside of the scale/balance is wet. 

 

Matter charged static electricity could influence the weighing. Discharge the static 

electricity. As example, the method is to use the electrification prevention spray, to 

spray it to both side of weighing platform. 

 

     

SPECIFICATIONS 

Model number i5500 

Capacity 100g 

Division 0.005g 

    Platter / Tray 

140

×

165mm

   

    Net/gross weight 

510/620g 

Standard carton: 29

×

22

×

14(cm

3

 

       

Package 

12 Units in one box: 60

×

45

×

45(cm

3

Operating Temperature 

0-40c (32-104

)) 

6

×

AA Size Batteries or AC/AC 

 

     

Power source 

Adapter 11V/150mA (optional) 

 
 
 

**SPECIAL WARNING** 

Cell-Phones, Cordless-Phones, and any radio-frequency device can 

cause temporary interference and cause the scale to temporarily not 

work properly.    Please do not use any electronic device near the i101.   

Just like in an Airplane, do not use your cell-phone near the scale 

when it is in use.    While there is NO risk of permanent damage to 

the scale, interference can cause an incorrect calibration or incorrect 

weight readings.   

 

 

 

FUNCTION SETTINGS 

4.

 

Enter function setting mode. 
The scale should be OFF.  Press

 and hold [UNIT]

 first, then press and 

release 

[ON/OFF] (while 

keeping 

[UNIT]

 pressed) the display will show 

LIGHT

 or 

A_OFF

 arrow and the display will show 888888 Now you can 

release the UNIT key. 
 
 

Summary of Contents for iBalance i5500

Page 1: ...cedure If necessary press ZERO key to set the display to 0 3 Place a given number of samples of an item on the pan the Sample Size should be either 10 20 50 or 100 pieces The weight of these samples will show on the display 4 Press the UNIT key several times to put the scale in PCS mode 5 Select the sample size the same as you chose above by pressing the PCS key press it as many times as necessary...

Page 2: ...causes damage if inside of the scale balance is wet Matter charged static electricity could influence the weighing Discharge the static electricity As example the method is to use the electrification prevention spray to spray it to both side of weighing platform 1 SPECIFICATIONS Model number i5500 Capacity 100g Division 0 005g Platter Tray 140 165mm Net gross weight 510 620g Standard carton 29 22 ...

Page 3: ... the scale OFF Press the ON OFF key then turn it back ON and check some weight readings If calibration is still incorrect repeat calibration but try it more slowly FEATURES z Auto shut off optional Auto calibration z Auto zero tracking Auto backlight optional z Low batter indication g oz lb ozt gn dwt ct n or z Large LCD 6digits 15 mm high g ct oz tl tola gn dwt z Large square weighting pan conver...

Page 4: ... possible please allow the balance to warm up for 10 minutes after first turning to power on so that the balance will function Properly and accurately Error messages EEEE Overload Low battery Calibration may be required before weighing Read CALIBRATION first and if necessary calibrate your scale balance for accurate weighing Weighing procedures 1 Press ON OFF to turn on the scale balance When powe...

Reviews: