- 34 -
123456789012345678
123456789012345678
123456789012345678
123456789012345678
EBA 551-06
•
EBA 551-06 LT
B
A
Maintenance work may only be performed by
trained staff.
Danger!
Disconnect the mains before starting any
service work or before removing the
cover.
Grease and oil the machine according to the
lubrication diagram after 1000 operating
hours or once a year. If the machine is subject
to excessive load then twice a year.
The hydraulic oil must be changed every 2000
operating hours or every 2 years.
Type of oil:
Aral Vitam DE 46 to DIN 51562.
Volume: approximately 7 litres.
(
A
) Drain screw
(
B
) Oil stick
• Check that the hydraulic pump and screws
are not leaking. If necessary tighten the
retaining nut.
• Check pressure. Maximum pressure
is 150 bar.
• Maintenance and cleaning •