- 31 -
A
2.
1.
3.
3.
4.
2.
1.
B
A
Position the main switch to "0" (
1.
)
Remove the 2 blade screws on the elongated
holes (
2.
). Then put the blade changing tool (
A
)
into place and fasten it to the blade (
3.
).
Remove 2 blade screws (
1.
)
IDEAL 4810-95/EP, IDEAL 4850-95/EP
and 3 blade screws (
1.
) IDEAL 5221-95EP,
IDEAL 6550-95EP.
Loosen the grips (
2.
) of the blade changing
tool (
A
) lightly and allow the blade to be taken
downwards out of the machine (
3.
). Place the
blade into the blade carrier (
B)
and screw it
into place (
4
).
•
Blade and cutting stick replacement
•