11
5.1.2
Three-phase connection 230V 3L
Cable
Cable
■
Brown
L1
■
Black
L2
■
Grey
L3
■
Green-yellow
Earth
Table 5: Three-phase cable 230V 3L Mychef.
5.1.3
Single-phase connection 230V L+N
Color
Cable
■
Brown
L1
■
Blue
Neutral
■
Green-yellow
Earth
Table 6: Single-phase cable 230V L+N Mychef.
5.2
Water connection
5.2.1
Water input
Cold water (max. 30°C)
¾
inch 150 to 400 kPa dynamic flow pressure
Drinking quality water with the following characteristics:
-
Hardness between 3º and 6º FH
-
PH between 6.5 and 8.5
-
Chlorides (Cl-) less than 30 mg/L
-
Chlorine (Cl2) less than 0.2 mg/L
-
Iron (Fe) less than 0.1 mg/L
-
Manganese (Mn) less than 0.05 mg/L
-
Copper (Cu) less than 0.05 mg/L
-
Conductivity less than 20uS/cm
Use of descaler and Mychef filter mandatory.
The use of water with different characteristics than those indicated may
cause serious problems in the components of the oven, such as corrosion
in the cooking chamber or of the glass, premature failure of the solenoid
valves, etc.
Summary of Contents for Bake
Page 1: ......