Never connect a phase to a neutral or grounding cable. Verify that the
installation voltages are correct for the appliance.
The appliance must be connected to the electric grid through a universal cut off switch
(three-phases and neutral) and with a contact openings distance of greater than 3 mm. Also
install a differential circuit breaker and an overcurrent protection.
Always ensure effective grounding.
Connect the equipment to an equipotential bonding system
using the contact
specially provided for this purpose (see equipotential symbol at the bottom right of the
appliance).
Connection to an equipotential system ensures additional safety in the
event of simultaneous failure of grounding leakage and differential failure.
Wiring and other safety devices used in the electrical installation should have the
appropriate cross-section for the appliance.
In any case, respect the regulations in force for the connection of the
equipment to the low voltage network.
5.1.2.
Evoline single-phase models
For proper connection after positioning, the device has a plug that connects to the grid.
Take the following precautions:
a)
Verify that the voltage / current source required by the appliance corresponds to its
electrical system (230V/16A).
b)
Grounding is mandatory. Verify that the outlet is grounded.
c)
Connect the appliance to an equipotential system
using the contact specially
provided for this purpose (see equipotential symbol at the bottom right of the
appliance).
Connection to an equipotential system ensures additional safety in the
event of simultaneous failure of grounding leakage and differential failure.