mychefcooking.com
PRODUCT MANUAL COOK PRO - DT.MP.CP.2201.2
60
Table 15. Periodic maintenance table
Mychef maintenance programme
2000 4000 6000 8000 10000 12000 14000 16000 18000 20000
Revision A
Firmware update
X
X
X
X
X
X
X
X
X
X
Water hardness check
X
X
X
X
X
X
X
X
X
X
Cleaning cooling fans
X
X
X
X
X
X
X
X
X
X
Electronic cleaning
X
X
X
X
X
X
X
X
X
X
Drain pan and siphon cleaning
X
X
X
X
X
X
X
X
X
X
Door gasket replacement and door adjustment
X
X
X
X
X
X
X
X
X
X
Revision B
Pathogen inactivator replacement (depending on model)
X
X
X
X
X
Temperature calibration
X
X
X
X
X
Adjustment of the inner bolts and nuts
X
X
X
X
X
Revision C
Replacement of chimney and drainpipes
X
X
Replacement of steam generation solenoid valve
X
X
Change resistor contactor (only models without TSC)
X
X
Revision D
Engine change
X
Replacement of resistor and gasket
X
Replacement of internal seals
X
Regular maintenance ensures that your oven will always work as designed.
Periodic maintenance must be proven for warranty validity.
Before any manipulation for maintenance or repair, the equipment must be
disconnected from the power supply.
If the power cable is damaged, it must be replaced by your after-sales
service or similarly qualified personnel in order to avoid hazards.