mychefcooking.com
PRODUCT MANUAL SNACK - DT.MP. SN.2202.2
53
start to count again from the left of the table. That is to say, at 22,000h the 2,000h revision
A would correspond.
Table 13. Periodic maintenance table
Regular maintenance ensures that your oven will always work as designed.
Periodic maintenance must be proven for warranty validity.
Before any manipulation for maintenance or repair, the equipment must be
disconnected from the mains supply.
If the power cord is damaged, it must be replaced by your after-sales service
or similarly qualified personnel in order to avoid hazards.
Mychef maintenance programme
2000 4000 6000 8000 10000 12000 14000 16000 18000 20000
Revision A
Firmware update
X
X
X
X
X
X
X
X
X
X
Water hardness check
X
X
X
X
X
X
X
X
X
X
Cleaning cooling fans
X
X
X
X
X
X
X
X
X
X
Electronic cleaning
X
X
X
X
X
X
X
X
X
X
Drain pan and siphon cleaning
X
X
X
X
X
X
X
X
X
X
Weatherstripping replacement and door adjustment
X
X
X
X
X
X
X
X
X
X
Revision B
Pathogen inactivator replacement (depending on model)
X
X
X
X
X
Temperature calibration
X
X
X
X
X
Adjustment of the inner bolts and nuts
X
X
X
X
X
Revision C
Replacement of chimney and drain pipes
X
X
Replacement of steam generation solenoid valve
X
X
Change resistor contactor (only models without TSC)
X
X
Revision D
Engine change
X
Replacement of resistor and gasket
X
Replacement of internal seals
X