2200LZJE-HO-C6-N_2013.12.
Chapter 3 Installation
Compound 2-stage Screw Compressor 2016**C
3.1 General Precautions for Installation
3-1
Chapter 3 Installation
3.1
General Precautions for Installation
This chapter (Installation) assumes that the compressor is installed to a standard refrigeration /
cold storage unit.
If the unit you are actually using is not the standard type refrigeration/cold storage unit, prepare a
proper installation manual by referring to the description in this chapter and paying due
consideration to safety, before installing the compressor.
If there are any questions, please contact our local sales offices or service centers.
In some cases, it may be required that installation is performed by qualified personnel. Make
sure that the work is performed by qualified personnel in compliance with local laws,
ordinances and other regulations/requirements.
Before installing the compressor, please read this chapter and related documents attentively
and fully understand their contents.
Electrical works should be performed only by electrical engineers.
3.2 Installation
Works
3.2.1 Unpacking
Check that there are no abnormalities such as damage on the compressor.
If there are abnormalities or deficient parts on the compressor, please contact our sales offices
or service centers immediately.
Unnecessary packing materials should be discarded according to the laws and ordinances, or
your company's rules.
3.2.2 Storage
Perform the followings to store the compressor before installation.
Store it indoors.
Infuse nitrogen gas into the compressor and seal it. (Pressure: Approximately 0.15 Mpa )
3.2.3 Transfer
Dropping of the lifted compressor may cause death or serious injury. Do not
stand under the lifted compressor.
1.
For lifting the compressor within the safety limit, use lifting equipment and tools appropriate for the
weight of compressor.
2.
Secure sufficient space for safe lifting.
3.
Always check the wire ropes before using them. Thoroughly check the wire ropes for problems
such as kinks, knots and broken strands. Do not perform lifting before checking the wire ropes. If
you cannot make a correct evaluation or judgment, entrust an expert to check.
4.
To lift the compressor, attach the wire ropes to the appended eye bolts by using appropriate
shackles and hooks. Use the eye bolts only for lifting the compressor. Do not use the eye bolts
when lifting the compressor together with additive equipment.