2200M4JE-HO-iS2-N_2014.04.
Chapter 1 Safety
Screw Compressor i-series
1.3
Residual Risks
1-4
1.3 Residual
Risks
The following information assumes that this product is operated or inspected/maintained as part of a
general package unit for refrigeration/cold storage. It is impossible to predict all the risk sources
involved in actual use of the package unit.
Devise appropriate countermeasures for hazardous sources in your systems.
Table 1-2
Hazardous Sources
Hazardous
sources
Predicted hazard
Measures to be taken
in operation
Measures to be taken
during cleaning,
inspection or parts
replacement
A Motor
and
compressor
coupling
Caught in or
entangled in due to
contact
Install cover on the
opening of coupling,
or prohibit opening.
Keep away.
Turn off motor main
power and control
power, and conduct
lockout/tagout.
B Motor
terminals
Electric shock caused
by contact with live
wires or electrical
leakage
Keep away.
Do not open terminal
boxes.
Do not touch terminal
boxes.
Turn off motor main
power and control
power, and conduct
lockout/tagout.
C Compressor
suction casing
Frostbite due to
contact
Contact with or
inhalation of
hazardous
substances generated
by leakage of
refrigerant or the like
Keep away and do not
touch.
Wear protective gear.
Detect gas leakage.
Wear protective gear.
Work under room
temperature.
D Compressor
discharge
casing and
discharge
piping
Burn injury due to
contact
Contact with or
inhalation of
hazardous
substances generated
by leakage or spout of
refrigerant or the like
Keep away and do not
touch.
Wear protective gear.
Detect gas leakage.
Wear protective gear.
Work at a temperature
of not higher than
40
°
C.
E Solenoid
valve
for controlling
compressor
capacity
Electric shock caused
by contact with live
wires or electrical
leakage
Install protective cover
on terminals, and
prohibit opening.
Keep away and do not
touch.
Wear protective gear.
Turn off each breaker
and the control power,
and conduct
lockout/tagout.
Wear protective gear.
F Package
Unit
Check valve,
service valve
and joint in
each section
Contact with or
inhalation of
hazardous
substances generated
by mishandling or
leakage
Frostbite or burn due
to contact
Sufficient ventilation
Indicate valve
open/close state.
Keep away and do not
touch.
Wear protective gear.
Sufficient ventilation
Wear protective gear.
Tagout for controlled
valve
G Package
Unit
Solenoid valve
or motor
operated
valve
Electric shock caused
by contact with live
wires or electrical
leakage
Pinched due to
contact with driving
part
Install protective cover
on terminals, and
prohibit opening.
Keep away and do not
touch.
Wear protective gear.
Turn off each breaker
and the control power,
and conduct
lockout/tagout.
Wear protective gear.