Programming
Programming Control Unit CH_SV V00
4/9
Note!
If in the programming mode no push button is pressed anymore fro 60s, the changed settings
will be reset and the control unit will leave the programming mode automatically.
3 Error messages
3.1 Reading error messages
This part describes how to start the reading of the last 10 error messages of the control
unit
3.1.1 Start reading
•
Switch off control unit or lock the emergency Stop button, close door
•
Press programming button „2“
•
Switch on control unit with pressed programming button „2“ or unlock the
emergency stop button
•
Approx. 5s later
P00
appears on the display
•
The control unit is ready for programming
3.1.2 Select program no.
•
Press programming button „1“ as often as necessary until the wished no. of the
program is indicated, counting upwards in this case
P50
•
By actuating the programming button „3“ it is possible to scroll backwards
3.1.3 Confirm subprogram no.
•
If the wished subprogram no. Is indicated, press programming button „2“ once.
The last error message appears (for example F01), after the error message appears
the storage space
U01
•
The control unit is in the program mode error message
•
You can scroll with the programming „1“ through the error list from the beginning
to the end. At the end
U10
appears
•
The last error is indicated first
•
A free error space without an error message the display shows --
3.1.4 Finish reading
•
When
PXX
is indicated, press programming button „2“ once
•
The pre selected program no.
P50
appears
either
Select a new program no. and change the subprogram no. according to it.
or
3.2 Finish programming
•
Press programming button „2“ for 5s
•
In the display the operation condition is shown accordingly
Note!
If in the programming mode no push button is pressed for 60s, the changed settings will be
reset and the control unit will leave the programming mode automatically.