background image

Programming

                                                                

                                        

Programming Control Unit CH_SV V00 

5/9

 

 

4  Operating cycles 

4.1  Reading operating cycles 

This part describes how to start the reading of the operating cycles of the control unit 
 

4.1.1  Start reading 

 

Switch off control unit or lock the emergency Stop button, close door 

 

Press programming button „3“ 

 

Switch on control unit with pressed programming button „3“ or unlock the 
emergency stop button 

 

Approx. 5s later 

S10 

appears on the display 

 

The control unit is ready for reading operating cycles 

 

4.1.2  Select operating cycles 

 

Press the programming button „1“ as often as necessary until the wished operating 
cycles is indicated, counting upwards 

 

S11

 

operating cycles dock leveler 

 

S12

 

operating cycles door 

 

S13

 

operating cycles inflatable shelter 

 

4.1.3  Select operating cycles 

 

If the wished operating cycle is indicated, press programming button „3“ once. 
The display shows flashing -- 

 

Press programming button „1“ once, the number starts automatically from left to 
right. A number with 8 digits will follow 

 

At the end of the number the display shows -- 

 

By pressing the programming button „1“ once again, the number starts a second 
time 

 

By pressing the programming button „3“ the display shows the pre selected 
operating cycles no. 

 

4.2  Finish operating cycles 

 

Select 

S10

 

 

Press programming button „3“ 5s 

 

the display shows the operating cycles accordingly 

 

Note!  

If in the programming mode no push button is pressed for 60s, the changed settings will be 
reset and the control unit will leave the programming mode automatically. 
 

5  Select inflatable shelter On/ Off 

This part describes how to choose the function inflatable shelter on/ off . This function 
is only for the control unit „ i305“. For this the service tool is not necessary. 

 

5.1  Function inflatable shelter On 

 

Dock leveler in resting position and door closed 

 

Press push button door „STOP“ 5s 

 

The two LED´s on the control units are flashing at the same time 

 

Release push button door „STOP“ 

 

Press push button „AUTO“ 

 

On the display appears 

S00

 

Summary of Contents for DS0290020

Page 1: ... 9 Hanover 05 08 2010 Project Control unit 105 105A i105 205A i205 i305 Project leader Document Programming control unit 105 105A i105 205A i205 i305 Version 00 Revision Copy Programming Programming button 1 Programming button 2 Programming button 3 ...

Page 2: ... Start reading 4 3 1 2 Select program no 4 3 1 3 Confirm subprogram no 4 3 1 4 Finish reading 4 3 2 FINISH PROGRAMMING 4 4 OPERATING CYCLES 5 4 1 READING OPERATING CYCLES 5 4 1 1 Start reading 5 4 1 2 Select operating cycles 5 4 1 3 Select operating cycles 5 4 2 FINISH OPERATING CYCLES 5 5 SELECT INFLATABLE SHELTER ON OFF 5 5 1 FUNCTION INFLATABLE SHELTER ON 5 5 2 FUNCTION INFLATABLE SHELTER OFF 6...

Page 3: ... no Press programming button 1 as often as necessary until the wished no Of the program is indicated counting upwards from P00 to P99 By actuating the programming button 3 it is possible to scroll backwards 2 1 3 Confirm program no If the wished program no Is indicated press the programming button 2 once The subprogram of the selected program no flashes 2 1 4 Select subprogram no Press programming...

Page 4: ...By actuating the programming button 3 it is possible to scroll backwards 3 1 3 Confirm subprogram no If the wished subprogram no Is indicated press programming button 2 once The last error message appears for example F01 after the error message appears the storage space U01 The control unit is in the program mode error message You can scroll with the programming 1 through the error list from the b...

Page 5: ...ess programming button 1 once the number starts automatically from left to right A number with 8 digits will follow At the end of the number the display shows By pressing the programming button 1 once again the number starts a second time By pressing the programming button 3 the display shows the pre selected operating cycles no 4 2 Finish operating cycles Select S10 Press programming button 3 5s ...

Page 6: ...or a photocell for the interlocking The description is only for control units 105 105A and 205A 6 1 Choose limit switch Replace the cable bridge on terminal X13 on pin 4 and 5 6 2 Choose photocell Insert a cable bridge on terminal X13 pin 4 and 5 Note The programming in the programming mode P05 has no influence on this 7 Indication on display description Function symbol Error and maintenance indic...

Page 7: ...eveler by photocell P05 U00 Motor power 2 6A U01 Motor power 3 2A U02 Motor power 3 8A U03 Motor power 4 4A U04 Motor power 5 0A U05 Motor power 5 6A U06 Motor power 6 2A U07 Motor power 6 8A U08 Motor power 7 4A U09 Motor power 8 0A U10 Motor power 8 6A U11 Motor power 9 2A P06 U00 Maintenance cycle 1000 U01 Maintenance cycle 1500 U02 Maintenance cycle 2000 U03 Maintenance cycle 2500 U04 Maintena...

Page 8: ...s U02 Automatic retraction 0 4s U03 Automatic retraction 0 6s U04 Automatic retraction 0 8s U05 Automatic retraction 1 0s U06 Automatic retraction 1 2s U07 Automatic retraction 1 4s U08 Automatic retraction 1 6s U09 Automatic retraction 1 8s U10 Automatic retraction 2 0s P14 U00 Delay door opens 0 0s U01 Delay door opens 5 0s U02 Delay door opens 10 0s U03 Delay door opens 15 0s U04 Delay door ope...

Page 9: ... over current hydraulic motor L2 U03 F03 over current hydraulic motor L3 U04 F04 phase sequence feedback signal contactor U05 F05 error Y1 defect U06 F06 error Y2 defect U07 F07 error Y1 is missing U08 F08 error Y2 is missing U09 F09 error RAM test U10 F10 error Flash Test F11 error push button F12 motor current detection defect F13 control voltage 24 V DC defect P99 U00 Factory settings hinged li...