Menus
Relay & Sensor Board Menu
(if installed)
Description
longer a voltage present
Boost 2
If a voltage is present on the eSense Input, Heater 2
will be boosted. The boost will end when there is no
longer a voltage present
Boost 1&2
If a voltage is present on the eSense Input, the
highest priority heater will be boosted. If the eSense
Input still has a voltage present after the heater
reaches maximum temperature, the other heater will
be boosted. The boost will end when there is no
longer a voltage present on eSense Input
Heater Enable…
Heater 1
The eSense input will act as an thermostat for Heater
1; the heater will only be able to be heated when
eSense has a voltage present
Heater 2
The eSense input will act as an thermostat for Heater
2; the heater will only be able to be heated when
eSense has a voltage present
Heater 1&2
The eSense input will act as an thermostat for both
Heater 1 and Heater 2; the heaters will only be able to
be heated when eSense has a voltage present
Boost Enable…
Boost Enable 1
The eSense input will act as an enable for the Boost
Timer for Heater 1. The Boost Timer has an additional
parameter 'e', when this option is set
See
Boost Timer
page 12
Boost Enable 2
The eSense input will act as an enable for the Boost
Timer for Heater 2. The Boost Timer has an additional
parameter 'e', when this option is set
See
Boost Timer
section for more details
Boost Enable
1&2
The eSense input will act as an enable for the Boost
Timer for Heater 1 and 2. The Boost Timer has an
additional parameter 'e', when this option is set
See
Boost Timer
page 12
18
eddi
operation and installation manual