Application Examples
Key for Wiring Diagram 1
eddi
device
Mains supply (230V AC from B16 circuit breaker or
13A fused spur)
Hot water cylinder
Heating element 1 (max. 3.7kW)
Isolator (20A double pole)
Auxiliary water heating boiler
Functional Description
This is the most simple installation and the most common.
A single heater is wired to the Heater 1 output.
The water in the cylinder (3) is heated with only surplus power until the thermostat has opened, the
eddi
will display
Max
Temp Reached
and the surplus power will then be exported until the water cools, heating will then resume.
An auxiliary heat source (e.g. a gas boiler) is set to heat the water either early in the morning or later in the evening,
depending on the home owners' lifestyle. Heating the water during times of generation (e.g. daylight hours) is best avoided
to allow maximum capacity for the surplus energy.
This is the default configuration for eddi; the settings do not need to be altered for this application.
Settings Required
Menu Option
Settings
Main Menu
Settings…
Display…
Icons…
Heater 1:
Water Top /
Water Bottom
Heater 2:
None
Priority…
Heater 1
operation and installation manual
eddi
33
1
2
3
6
5
4