Application Examples
Key for Wiring Diagram 7
eddi
device
Mains supply (230V AC from B16 circuit breaker or
13A fused spur)
Hot water cylinder
Water heating element (max. 3.7kW)
Isolator (20A double pole)
Relay & Sensor Board (optional add-on for
eddi
)
Temperature probe (type PT1000) (optional)
Mains supply for underfloor heating controller
Underfloor heating mat (max. 3.7kW)
Underfloor heating controller or thermostat
Functional Description
As well as water heating,
eddi
can be used with electric underfloor heating mats. In this application the water is heated as
priority and when fully heated, the surplus power is instead diverted to the underfloor heating mat.
Heater 1 (the immersion heater in the hot water cylinder) is heated with surplus power until the water is hot and the
thermostat opens, then
eddi
will immediately switch over to Heater 2 (the underfloor heating mat) (9) and continue
diverting the surplus power.
During heating of the lower priority heater (Heater 2),
eddi
will switch back to the higher priority heater (Heater 1) every 15
mins to check if it can store any more heat.
The heating priority can be changed in the
Main Menu
(
Priority
).
The underfloor heating controller or thermostat (10) is wired to the eSense input of the Relay & Sensor Board (6). The
eSense Input
setting is set to
Heater Enable 2
so only when the thermostat is calling for heat will
eddi
apply power
to the mat. When the underfloor heating thermostat is open
eddi
will display
Max Temp Reached
.
Installation of the temperature probe (7) is optional; the immersion heaters' mechanical thermostat is used by
eddi
if water
temperature reading is not required.
Settings Required
Menu Option
Settings
Main Menu
Settings…
Display…
Icons…
Heater 1:
Top Immersion /
Bottom Immersion
Heater 2:
Underfloor
Priority…
Heater 1
Advanced Menu…
Relays &
Sensors…
Temperatures…
Set Temperatures as
required if using
temperature probes
eSense Input…
Heater Enable…
Heater 2
operation and installation manual