2.2
TECHNICAL DATA
2.3
OPERATOR
DIMENSION
S
MYASTER 3 NEW
= 620 -
MYASTER 4 NEW
= 720
MYASTER 5 NEW
= 820 -
MYASTER 6 NEW
= 920
MYASTER 3 NEW
= 940 -
MYASTER 4 NEW
= 1140
MYASTER 5 NEW
= 1340 -
MYASTER 6 NEW
= 1540
159 mm
172 mm
117117
104104
53
53
Motor
24V
Motor
230/115V
64
MYASTER 3 NEW
230V-50Hz
1,7
280
8
150°
2800
44
1400
100°
17"
350
2,00
40%
Power supply
Max. motor voltage
Rated power
Capacitor
Thermal cut off
Rated thrust
Ip rating
Revolutions
Max.opening angle
Opening time - 90°
Max. leaf weight
Max. leaf length
Duty cycle
V
A
W
µF
C°
N
IP
rpm
deg
s
Kg
m
%
24Vdc
0,75
50
--
--
2500
44
1
7
00
100°
13,5
"
275
2,00
80%
115V-60Hz
2,3
300
30
150°
3000
44
1700
100°
14"
300
2,00
40%
230V-50Hz
1,7
280
8
150°
2800
44
1400
110°
22"
350
2,8
40%
24Vdc
0,75
50
--
--
2500
44
1
7
00
110°
18
"
250
2,50
80%
115V-60Hz
2,3
300
30
150°
3000
44
1700
110°
18"
300
2,8
40%
230V-50Hz
1,7
280
8
150°
2800
44
1400
110°
27"
250
3,50
40%
24Vdc
0,75
50
--
--
2500
44
1
7
00
110°
2
2,5
"
150
3,00
80%
115V-60Hz
2,3
300
30
150°
3000
44
1700
110°
22"
200
3,50
40%
230V-50Hz
1,7
280
8
150°
2800
44
1400
120°
32"
250
4,00
40%
3. INSTALLA
TION
3.1
PRELIMINARY CHECKS
Before proceeding to installation, it is necessary to double check the good condition of every component
and make sure the site is suitable for installation purposes.
•
All components must be integral and suitable to use.
•
Make sure the area around the system is clear enough to allow eazy and safe manual operation.
•
Make sure weight, dimensions and gate features are suitable to the model you have choosen.
•
Make sure the gate area is fitted with ground stops both in opening and closing.
•
Make sure the gate is mechanically free of friction.
•
Make sure the automation fixing area is compatible with the dimensions of the brackets and that there is
sufficient space to carry out manual operation easily and safely.
•
Make sure the automation positioning area is not subject to flooding.
•
Make sure the electric circuit is connected to a state of the art safety grounding.
•
Make sure the fixing surfaces of the photocells are flat and allow correct alignment between transmitter and
receiver.
2
rev01_22
MYASTER 4 NEW
MYASTER 5 NEW
MYASTER 6