Key switch
Blinker
3.3
WIRING INSTALLATION OVERVIEW
NB
: Cables necessary for the installation of the system (not included) may vary according to the quantity
and type of accessories and devices fitted.
•
Switch the POWER OFF before starting any wiring.
•
Fit a power cut switch to protect the electric plant against overcurrent.
The standard requires a separation of contacts of at least 3 mm in each pole(EN 60335-1).
•
The installation requires skills in the electrical and mechanical fields; it must only be performed by qualified
personnel able to release the declaration of conformity (type A) on the whole installation (Machine Directive
2006/42/CEE, attachment IIA).
•
The main electric plant shall comply with the oustanding regulation and shall be state of the art carried out.
•
The power supply lines to the motors, control unit and accessories must be separated in order to avoid possible
interferences that could generate system malfunctions.
•
The electric cable coming out of the actuator must not be stretched but make a wide downward curve to
avoid the backflow of water inside the actuator itself (see the picture above).
B
Operator
Control unit
C
C¹
D
E
F
RX photocell
TX photocell
Antenna
Radio receiver
ELENCO CAVI PER I VARI DISPOSITIVI
A
G
pic.
B
4
rev01_22
pic.
A
3 x 1,5 mm² + Terra
2 x 1,5 mm² + Terra
4 x 0,5 mm²
2 x 0,5 mm²
2 x 0,5 mm²
230V/115V
2 x 0,5 mm²
2 x 0,5 mm²
RG58
24V
2 x 0,5 mm²
2 x 0,5 mm²
4 x 0,5 mm²
2 x 0,5 mm²
RG58
2 x 0,5 mm²
2 x 1,5 mm²
2 x 1,5 mm² + Terra